IC ENERGY METERING 1PHASE 28SSOP

CS5467-ISZ

Manufacturer Part Number
CS5467-ISZ
Description
IC ENERGY METERING 1PHASE 28SSOP
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5467-ISZ

Package / Case
28-SSOP
Input Impedance
30 KOhm
Measurement Error
0.1%
Voltage - I/o High
0.8V
Voltage - I/o Low
0.2V
Current - Supply
3.5mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Meter Type
Single Phase
Output Voltage Range
2.4 V to 2.6 V
Input Voltage Range
2.4 V to 2.6 V
Input Current
100 nA
Power Dissipation
500 mW
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1555 - BOARD EVAL FOR CS5467 ADC
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1197-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5467-ISZ
Manufacturer:
CIRRUSLOGIC
Quantity:
20 000
Company:
Part Number:
CS5467-ISZR
Quantity:
690
8.3.11 Temperature Gain (T
8.3.12 Temperature Offset (T
8.3.13 Filter Settling Time for Conversion Startup (T
8.3.14 No Load Threshold (Load
8.3.15 Voltage Fixed RMS Reference (VF
DS714F1
MSB
MSB
MSB
MSB
MSB
-(2
-(2
-(2
2
2
23
6
0
0
0
)
)
)
Default = 0x2F02C3
Refer to
Default = 0xF3D35A
Refer to
Default = 30
Sets the number of output word rate (OWR) samples that will be used to allow filters to settle at the beginning
of Conversion and Calibration commands. This is an integer in the range of 0 to 8,388,607 samples.
Default = 0
Load
E
Load
MSB. Negative values are not used.
Default = 0.7071068 (full scale RMS)
If the application program detects that the meter has possibly been tampered with in such a manner that the
voltage input is no longer working, it may choose to use this internal RMS reference instead of the disabled
voltage input by setting the VFIX bit in the Modes register. This is a two's complement value in the range of
0 ≤ value < 1.0, with the binary point to the right of the MSB. Negative values are not used.
PULSE
2
2
2
2
2
22
-1
-1
-1
5
MIN
MIN
will be zeroed. If the magnitude of the
6.13 Temperature Measurement
6.13 Temperature Measurement
is used to set the no load threshold. When the magnitude of the E
is a two’s compliment value in the range of -1.0 ≤ value < 1.0, with the binary point to the right of the
2
2
2
2
2
21
-2
-2
-2
4
2
2
2
2
2
20
-3
-3
-3
3
2
2
2
2
2
GAIN
19
-4
-4
-4
2
OFF
MIN
)
)
2
2
2
2
2
– Address: 22
18
– Address: 23
-5
-5
-5
1
)
Address: 26
2
2
2
2
2
17
-6
-6
-6
0
RMS
on page 22 for more information.
on page 22 for more information.
)
2
2
2
2
2
Q
16
-1
-7
-7
-7
PULSE
Address 27
SETTLE
.....
.....
.....
.....
.....
register is less than Load
) – Address: 25
2
2
2
2
2
-11
-17
-17
-17
6
2
2
2
2
2
-12
-18
-18
-18
5
PULSE
2
2
2
2
2
-13
-19
-19
-19
4
register is less than Load
MIN
2
2
2
2
2
-14
-20
-20
-20
3
,
Q
pulse
2
2
2
2
2
-15
-21
-21
-21
2
will be zeroed.
CS5467
2
2
2
2
2
-16
-22
-22
-22
1
LSB
LSB
LSB
LSB
LSB
2
2
2
2
2
-17
-23
-23
MIN
-23
0
37
,

Related parts for CS5467-ISZ