DS2756E+ Maxim Integrated Products, DS2756E+ Datasheet - Page 14

IC FUEL GAUGE BATT 8TSSOP

DS2756E+

Manufacturer Part Number
DS2756E+
Description
IC FUEL GAUGE BATT 8TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS2756E+

Function
Fuel, Gas Gauge/Monitor
Battery Type
Lithium-Ion (Li-Ion), Lithium-Polymer (Li-Pol)
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-TSSOP
Operating Supply Voltage
3 V to 5.5 V
Supply Current
75 uA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Charge Safety Timers
Yes
Mounting Style
SMD/SMT
Temperature Monitoring
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Figure 12. Alarm And Suspend Mode Operating Diagram
TEMPERATURE
Discharge Suspend
Interrupt Threshold
Interrupt Threshold
Interrupt Threshold
Interrupt Threshold
Interrupt Threshold
Interrupt Threshold
High Temperature
High Accumulator
Low Temperature
Low Accumulator
Charge Suspend
CURRENT
Interrupt Enable
Interrupt Enable
Programmable
DEVICE
Note 1.
Note 2.
Note 3.
Note 4.
Note 5.
STATE
(IOS = 0)
ACR
PIO
PIE
IE
Threshold violations do not generate alarm interrupts until the Interrupt Enable (IE) bit is set.
PIO Interrupts are cleared by resetting the PIO bit in the Special Feature Register.
SUSPEND state shown in this timing diagram refers to the DS2756 cycling between Active
and Suspend mode at a rate determined by the PIE bit settings. Suspend state is entered by
setting PIE bits to a non-zero value, setting PMOD=1, and then driving DQ low for longer
than 2s.
Interrupts on PIO not reset by software are automatically cleared when entering suspend
mode.
Alarm threshold violations do not generate interrupts if Suspend mode is enabled
(PIE ≠ 00b).
ACTIVE
00b
Note 1
Note 2
14 of 27
Note 3
SUSPEND
00b
ACTIVE
Note 4
Note 5
SUSPEND