XBP24-BPIT-004 Digi International, XBP24-BPIT-004 Datasheet - Page 75

no-image

XBP24-BPIT-004

Manufacturer Part Number
XBP24-BPIT-004
Description
Zigbee / 802.15.4 Modules XBee-PRO Znet 2.5 PCB Antenna
Manufacturer
Digi International
Datasheet

Specifications of XBP24-BPIT-004

Rohs
yes
Frequency Band
2.4 GHz
Line Of Sight Range
100 m
Data Rate
250 Kbps
Sensitivity
- 102 dBm
Operating Supply Voltage
3 V to 3.4 V
Output Power
63 mW
Antenna Connector Type
PCB
Maximum Operating Temperature
+ 85 C
1. Node types that support the command: C = Coordinator, R = Router, E = End Device
2. Command supported by modules using API firmware only
I/O Commands
XBee ZNet 2.5/XBee‐PRO ZNet 2.5 ZigBee OEM RF Modules v1.x4x 
Table 7‐06. Serial Interfacing Commands
Table 7‐07. I/O Commands
AT
Command
NB
RO
D7
D6
AT
Command
IS
1S
IR
IC
P0
P1
P2
Name and Description
Serial Parity. Set/Read the serial parity setting on the module.
Packetization Timeout. Set/Read number of character times of inter-character silence
required before packetization. Set (RO=0) to transmit characters as they arrive instead of
buffering them into one RF packet.
DIO7 Configuration. Select/Read options for the DIO7 line of the RF module.
DIO6 Configuration. Configure options for the DIO6 line of the RF module.
Name and Description
Force Sample Forces a read of all enabled digital and analog input lines.
XBee Sensor Sample. Forces a sample to be taken on an XBee Sensor device. This
command can only be issued to an XBee sensor device using an API remote command.
IO Sample Rate. Set/Read the IO sample rate to enable periodic sampling. For periodic
sampling to be enabled, IR must be set to a non-zero value, and at least one module pin
must have analog or digital IO functionality enabled (see D0-D8, P0-P2 commands).
The sample rate is measured in milliseconds.
IO Digital Change Detection. Set/Read the digital IO pins to monitor for changes in the
IO state. IC works with the individual pin configuration commands (D0-D8, P0-P2). If a
pin is enabled as a digital input/output, the IC command can be used to force an
immediate IO sample transmission when the DIO state changes. IC is a bitmask that
can be used to enable or disable edge detection on individual channels. Unused bits
should be set to 0.
Bit (IO pin): 0 (DIO0)4 (DIO4)8 (DIO8)
PWM0 Configuration. Select/Read function for PWM0.
DIO11 Configuration. Configure options for the DIO11 line of the RF module.
DIO12 Configuration. Configure options for the DIO12 line of the RF module.
1 (DIO1) 5 (DIO5) 9 (DIO9)
2 (DIO2) 6 (DIO6) 10 (DIO10)
3 (DIO3) 7 (DIO7) 11 (DIO11)
© 2008 Digi International, Inc.
Node
Type
CRE
CRE
CRE
CRE
Node
Type
CRE
RE
CRE
CRE
CRE
CRE
CRE
1
1
Parameter Range
0 = No parity
1 = Even parity
2 = Odd parity
3 = Mark parity
0 - 0xFF
0 = Disabled
1 = CTS Flow Control
3 = Digital input
4 = Digital output, low
5 = Digital output, high
6 = RS-485 transmit
enable (low enable)
7 = RS-485 transmit
enable (high enable)
0 - Disabled
1 - RTS Flow Control
Parameter Range
--
-
0 - 0xFFFF (ms)
: 0 - 0xFFFF
0 = Disabled
1 = RSSI PWM
3 - Digital input,
monitored
4 - Digital output, default
low
5 - Digital output, default
high
0 - Unmonitored digital
input
3- Digital input,
monitored
4- Digital output, default
low
5- Digital output, default
high
0 - Unmonitored digital
input
3- Digital input,
monitored
4- Digital output, default
low
5- Digital output, default
high
[x character times]
Default
0
3
1
0
Default
--
-
0
0
1
0
0
     74

Related parts for XBP24-BPIT-004