SCC1300-D02DEMO Murata Electronics, SCC1300-D02DEMO Datasheet - Page 9

no-image

SCC1300-D02DEMO

Manufacturer Part Number
SCC1300-D02DEMO
Description
Acceleration Sensor Development Tools SCC1300-D02 Demo Board
Manufacturer
Murata Electronics
Datasheet

Specifications of SCC1300-D02DEMO

Tool Is For Evaluation Of
SCA1300-D02
Acceleration
2 g
Sensing Axis
Triple Axis
Interface Type
SPI
Operating Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Current
24 mA
Output Type
Analog and Digital
5
Acceleration data can be saved from GUI software by pressing the “Save to file” button (
VTI Technologies Oy
www.vti.fi
Advanced data logging
Figure 2). Data can be logged also by using the Windows HyperTerminal software and macro
language that is used to control the MCU of the SCC1300 Demo Kit.
Please notice that GUI software and Windows HyperTerminal software can not be open at the
same time. Follow the steps below to start the data logging:
Macro language is used to control the SCC1300 DEMO KIT. It can be also used to configure the
SCC1300 sensor. For more detailed information of macro language, please refer to “SCA3000
DEMO KIT macro language description 8259200”.
1. Connect SCC1300 Demo Kit with USB cable to PC
2. Open GUI software to see the correct COM port number (SETUP display, see Error!
3. Close the GUI software.
4. Open Windows HyperTerminal software from CD-ROM:
5. Press demo reset button (see Figure 1). SCC1300 Demo Kit sends an info text to
6. After the info text appears on HyperTerminal, send the wanted macro text file, such as
7. The text file is a macro that runs in an endless loop. The macro sends angular rate and 3-
8. The data can be stored by capturing the data in to file:
9. Data capturing can be stopped from:
Reference source not found.). Windows Device Manager can also be used to find out the
COM port number.
HyperTerminal (see Figure 9). If the HyperTerminal software is unable to connect the
SCC1300 Demo Kit or the info text does not appear,
until info text appears to HyperTerminal screen (see Figure 9).
“SCC1300_data_logger.txt” from CD-ROM (“Transfer” pull down menu → “Send Text
File…” → browse for
SCC1300_data_logger_macro.txt)
axis acceleration data in hex format to HyperTerminal (see Figure 10). Example of data
format:
0x0025,0x004c,0x0008,0x0a1c,G-X-Y-Z
where “0x” indicates for hex format, and “G-Z-Y-X” the axis order.
“Transfer” pull down menu → “Capture Text…” → save captured data into wanted file and
folder.
“Transfer” pull down menu → “Capture Text…” → “Stop”
-
-
-
-
“SCC1300_demo_HyperTerminal_connection.ht”, or
see detailed serial communication settings in Table 2.
Press disconnect
change the COM port number to correct from port properties
press connect
press reset button on SCC1300 Demo Kit.
Doc.Nr. 82117600.01
,
,
SCC1300 GYRO-COMBO DEMO KIT
,
User Manual
Rev.0.1
9/19