wm8350 Wolfson Microelectronics plc, wm8350 Datasheet - Page 72

no-image

wm8350

Manufacturer Part Number
wm8350
Description
Wolfson Audioplus? Stereo Codec With Power Management
Manufacturer
Wolfson Microelectronics plc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
wm8350G
Manufacturer:
WOLFSON
Quantity:
20 000
Part Number:
wm8350GEB/RVLRG
Manufacturer:
WOLFSON
Quantity:
20 000
WM8350
w
R11 (0Bh)
Power
Mgmt
R64 (40h)
ADC
Control
Note: ADC_HPF_ENA can be accessed through R11 or through R64. Reading from or writing to
either register location has the same effect.
ADDRESS
13.5.1
Programmable digital volume control is provided to attenuate the ADC’s output signal.
R66 (42h)
ADC Digital
Volume L
R67 (43h)
ADC Digital
Volume R
Table 27 ADC Volume Control
13.5.2
A digital high-pass filter is provided to remove DC offsets from the ADC signal.
Table 28 Controlling the ADC High-pass Filter
ADDRESS
ADC VOLUME CONTROL
ADC HIGH-PASS FILTER
BIT
9:8
13
15
BIT
7:0
7:0
8
8
ADC_HPF_EN
A
ADC_HPF_CU
T [1:0]
ADC_VU
ADCL_VO
L [7:0]
ADC_VU
ADCR_VO
L [7:0]
LABEL
LABEL
DEFAULT
1100_000
1100_000
DEFAULT
0
0
0
0
00
0
ADC left and ADC right volume do not update
until a 1 is written to either ADC_VU register
bit.
Left ADC Digital Volume Control
0000 0000 = Digital Mute
0000 0001 = -71.625dB
0000 0010 = -71.25dB
... 0.375dB steps up to
1110 1111 = +17.625dB
ADC left and ADC right volume do not update
until a 1 is written to either ADC_VU register
bit.
Right ADC Digital Volume Control
0000 0000 = Digital Mute
0000 0001 = -71.625dB
0000 0010 = -71.25dB
... 0.375dB steps up to
1110 1111 = +17.625dB
High Pass Filter enable
0 = disabled
1 = enabled
Select cut-off frequency for high-pass filter
00 = 2^-11 (first order) = 3.7Hz @
fs=44.1kHz
01 = 2^-5 (2nd order) = ~250Hz @ fs=8kHz
10 = 2^-4 (2nd order) = ~250Hz @ fs=16kHz
11 = 2^-3 (2nd order) = ~250Hz @ fs=32kHz
DESCRIPTION
DESCRIPTION
PD, June 2009, Rev 4.1
Production Data
72

Related parts for wm8350