wm8350 Wolfson Microelectronics plc, wm8350 Datasheet - Page 232

no-image

wm8350

Manufacturer Part Number
wm8350
Description
Wolfson Audioplus? Stereo Codec With Power Management
Manufacturer
Wolfson Microelectronics plc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
wm8350G
Manufacturer:
WOLFSON
Quantity:
20 000
Part Number:
wm8350GEB/RVLRG
Manufacturer:
WOLFSON
Quantity:
20 000
WM8350
Register 0Dh Power mgmt (6)
w
REGISTER
ADDRESS
BIT
9
8
5
4
3
2
1
0
LDO2_ENA
LDO1_ENA
DC6_ENA
DC5_ENA
DC4_ENA
DC3_ENA
DC2_ENA
DC1_ENA
LABEL
DEFAULT
0
0
0
0
0
0
0
0
LDO2 enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
LDO1 enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DCDC6 converter enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DCDC5 converter enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DCDC4 converter enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DCDC3 converter enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DCDC2 converter enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DCDC1 converter enable
0 = disabled
1 = enabled
Note: internal conditions may prevent the converter
from actually switching on - see DCDC/LDO Status
register for actual converter status.
Reset by state machine. Default held in metal mask.
DESCRIPTION
PD, June 2009, Rev 4.1
REFER TO
Production Data
232