epm9560wc208-20c Altera Corporation, epm9560wc208-20c Datasheet - Page 21
epm9560wc208-20c
Manufacturer Part Number
epm9560wc208-20c
Description
Programmable Logic Device Family
Manufacturer
Altera Corporation
Datasheet
1.EPM9560WC208-20C.pdf
(46 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Altera Corporation
By combining the pulse and shift times for each of the programming
stages, the program or verify time can be derived as a function of the TCK
frequency, the number of devices, and specific target device(s). Because
different ISP-capable devices have a different number of EEPROM cells,
both the total fixed and total variable times are unique for a single device.
Programming a Single MAX 9000 Device
The time required to program a single MAX 9000 device in-system can be
calculated from the following formula:
where: t
The ISP times for a stand-alone verification of a single MAX 9000 device
can be calculated from the following formula:
where: t
t
t
PR OG
VER
=
=
t
VPULSE
t
Cycle
f
t
Cycle
TCK
t
PROG
PPULSE
VER
VPULSE
PP ULSE
PTCK
VTCK
+
+
C ycle
--------------------------------
MAX 9000 Programmable Logic Device Family Data Sheet
Cyc le
------------------------------- -
= Programming time
= Sum of the fixed times to erase, program, and
= Number of TCK cycles to program a device
= TCK frequency
f
= Verify time
= Sum of the fixed times to verify the EEPROM cells
= Number of TCK cycles to verify a device
TC K
f
T CK
VTC K
verify the EEPROM cells
PTC K
21