epm9560wc208-20c Altera Corporation, epm9560wc208-20c Datasheet - Page 15

no-image

epm9560wc208-20c

Manufacturer Part Number
epm9560wc208-20c
Description
Programmable Logic Device Family
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM9560WC208-20C
Manufacturer:
ALTERA
0
Altera Corporation
A row interconnect channel can be fed by the output of the macrocell
through a 4-to-1 multiplexer that the macrocell shares with three column
channels. If the multiplexer is used for a macrocell-to-row connection, the
three column signals can access another row channel via an additional
3-to-1 multiplexer. Within any LAB, the multiplexers provide all
48 column channels with access to 32 row channels.
Row-to-I/O Cell Connections
Figure 8
and IOCs. An input signal from an IOC can drive two separate row
channels. When an IOC is used as an output, the signal is driven by a
10-to-1 multiplexer that selects the row channels. Each end of the row
channel feeds up to eight IOCs on the periphery of the device.
Figure 8. MAX 9000 Row-to-IOC Connections
Column-to-I/O Cell Connections
Each end of a column channel has up to 10 IOCs (see
signal from an IOC can drive two separate column channels. When an IOC
is used as an output, the signal is driven by a 17-to-1 multiplexer that
selects the column channels.
Row FastTrack
Interconnect
illustrates the connections between row interconnect channels
96
MAX 9000 Programmable Logic Device Family Data Sheet
96
96
Each IOC can drive up to
two row channels.
10
10
Each IOC is driven by
a 10-to-1 multiplexer.
IOC1
IOC8
Figure
9). An input
15

Related parts for epm9560wc208-20c