pca9624 NXP Semiconductors, pca9624 Datasheet - Page 8

no-image

pca9624

Manufacturer Part Number
pca9624
Description
8-bit Fm+ I2c-bus 100 Ma 40 V Led Driver
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pca9624PW
Manufacturer:
PHILIPS
Quantity:
5 542
Part Number:
pca9624PW
Manufacturer:
NXP
Quantity:
2 924
Part Number:
pca9624PW
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
pca9624PW
Quantity:
5 000
Part Number:
pca9624PW,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9624PW,118
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9624PW118
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
pca9624PWЈ¬112
Manufacturer:
NXP
Quantity:
551
NXP Semiconductors
PCA9624_1
Product data sheet
7.2 Control register
Following the successful acknowledgement of the slave address, LED All Call address or
LED Sub Call address, the bus master will send a byte to the PCA9624, which will be
stored in the Control register.
The lowest 5 bits are used as a pointer to determine which register will be accessed
(D[4:0]). The highest 3 bits are used as Auto-Increment flag and Auto-Increment options
(AI[2:0]).
When the Auto-Increment flag is set (AI2 = logic 1), the five low order bits of the Control
register are automatically incremented after a read or write. This allows the user to
program the registers sequentially. Four different types of Auto-Increment are possible,
depending on AI1 and AI0 values.
Table 3.
Remark: Other combinations not shown in
reserved and must not be used for proper device operation.
AI[2:0] = 000 is used when the same register must be accessed several times during a
single I
is overwritten each time the register is accessed during a write operation.
AI[2:0] = 100 is used when all the registers must be sequentially accessed, for example,
power-up programming.
AI[2:0] = 101 is used when the 16 LED drivers must be individually programmed with
different values during the same I
setting to another color setting.
AI2
0
1
1
1
1
Fig 6.
2
AI1
0
0
0
1
1
C-bus communication, for example, changes the brightness of a single LED. Data
reset state = 80h
Remark: The Control register does not apply to the Software Reset I
Control register
Auto-Increment options
AI0
0
0
1
0
1
Function
no Auto-Increment
Auto-Increment for all registers. D[4:0] roll over to 00h after the last
register (11h) is accessed.
Auto-Increment for individual brightness registers only. D[4:0] roll over to
02h after the last register (11h) is accessed.
Auto-Increment for global control registers only. D[4:0] roll over to 0Ah’
after the last register (0Bh) is accessed.
Auto-Increment for individual and global control registers only. D[4:0] roll
over to 02h after the last register (0Bh) is accessed.
Rev. 01 — 3 June 2009
AI2 AI1 AI0 D4
Auto-Increment flag
Auto-Increment options
2
C-bus communication, for example, changing color
Table 3
8-bit Fm+ I
register address
D3
D2
(AI[2:0] = 001, 010, and 011) are
D1
002aac147
2
C-bus 100 mA 40 V LED driver
D0
2
C-bus address.
PCA9624
© NXP B.V. 2009. All rights reserved.
8 of 34