TS87C51RD2 ATMEL Corporation, TS87C51RD2 Datasheet - Page 22

no-image

TS87C51RD2

Manufacturer Part Number
TS87C51RD2
Description
(TS8xC51Rx2) High Performance 8-bit Microcontroller
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TS87C51RD2-LCB
Manufacturer:
TEMIC
Quantity:
68
Part Number:
TS87C51RD2-LCB
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS87C51RD2-LCE
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS87C51RD2-LCL
Manufacturer:
Atmel
Quantity:
10 000
Company:
Part Number:
TS87C51RD2-LCL
Quantity:
304
Part Number:
TS87C51RD2-LCMD
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS87C51RD2-LIB
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS87C51RD2-LIE
Manufacturer:
ATMEL
Quantity:
2 151
Part Number:
TS87C51RD2-MCA
Manufacturer:
TEMIC
Quantity:
124
Part Number:
TS87C51RD2-MCA
Manufacturer:
TEMIC
Quantity:
126
Part Number:
TS87C51RD2-MCB
Manufacturer:
INTEL
Quantity:
20 000
Part Number:
TS87C51RD2-MIA
Manufacturer:
TEMIC
Quantity:
31
22
AT/TS8xC51Rx2
Reset Value = 0000 0000b
Bit addressable
Table 6-3.
Number
Bit
7
6
5
4
3
2
1
0
7
-
Mnemonic
CP/RL2#
EXEN2
C/T2#
RCLK
EXF2
TCLK
T2MOD Register
T2MOD - Timer 2 Mode Control Register (C9h)
TR2
TF2
Bit
6
-
Description
Timer 2 overflow Flag
Must be cleared by software.
Set by hardware on timer 2 overflow, if RCLK = 0 and TCLK = 0.
Timer 2 External Flag
Set when a capture or a reload is caused by a negative transition on T2EX pin if
EXEN2=1.
When set, causes the CPU to vector to timer 2 interrupt routine when timer 2 interrupt is
enabled.
Must be cleared by software. EXF2 doesn’t cause an interrupt in Up/down counter mode
(DCEN = 1)
Receive Clock bit
Clear to use timer 1 overflow as receive clock for serial port in mode 1 or 3.
Set to use timer 2 overflow as receive clock for serial port in mode 1 or 3.
Transmit Clock bit
Clear to use timer 1 overflow as transmit clock for serial port in mode 1 or 3.
Set to use timer 2 overflow as transmit clock for serial port in mode 1 or 3.
Timer 2 External Enable bit
Clear to ignore events on T2EX pin for timer 2 operation.
Set to cause a capture or reload when a negative transition on T2EX pin is detected, if
timer 2 is not used to clock the serial port.
Timer 2 Run control bit
Clear to turn off timer 2.
Set to turn on timer 2.
Timer/Counter 2 select bit
Clear for timer operation (input from internal clock system: F
Set for counter operation (input from T2 input pin, falling edge trigger). Must be 0 for clock
out mode.
Timer 2 Capture/Reload bit
If RCLK=1 or TCLK=1, CP/RL2# is ignored and timer is forced to auto-reload on timer 2
overflow.
Clear to auto-reload on timer 2 overflows or negative transitions on T2EX pin if EXEN2=1.
Set to capture on negative transitions on T2EX pin if EXEN2=1.
5
-
4
-
3
-
2
-
OSC
).
T2OE
1
4188E–8051–08/06
DCEN
0

Related parts for TS87C51RD2