TLE84110EL Infineon Technologies, TLE84110EL Datasheet - Page 26

no-image

TLE84110EL

Manufacturer Part Number
TLE84110EL
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE84110EL

Packages
PG-SSOP-24
Ipeak
10 x 0.8
Inhibit
y
Iq (typ)
2.0 µA
Mounting
SMIT
Technology
BCD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE84110EL
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
TLE84110EL
0
Company:
Part Number:
TLE84110EL
Quantity:
4 800
6.3.2
Diagnosis Register Overview
Diagnosis Register 0 for HB 1 : HB 6
Diagnosis Register 1 for HB 7 : HB 10
Table 4
Bit
Activate Half-Bridge X
12
11
Data Sheet
Diagnosis & Register Control
15
14
13
OC
OC
15
15
SACT_HB 6
SACT_HB 5
Status
Register - 0
HB 1:6
OC
(HB1:6)
PSF
OL
(HB1:6)
PSF
PSF
14
14
Diagnosis - Word
Output (Status) Data Register
OL
OL
13
13
SACT_
HB6
Status
Register - 1
HB 7:10
OC
(HB7:10)
OL
(HB7:10)
X
X
12
12
X
SACT_
HB5
11
11
X
SACT_
SACT_
HB10
HB4
10
10
Status Register- 0
HB 1:6
DESCRIPTION
Overcurrent Error is set if any one of
HB1 to HB6 has an overload, short
circuit or cross current; The error is
latched and the corresponding output
is switched off;
Bit 15 error can only be reset via SRR
or power-on reset.
Power Supply Failure; Global Error Flag;
Bit 14 is set if VS has an overvoltage or undervoltage condition;
All outputs are switched OFF.
Bit 14 is automatically reset if VS returns to its normal operating range.
Open Load Error is set if any one of
HB1 to HB6 has a true open load or
underload error condition; The error
is latched. The corresponding output
is switched off if Bit 13, OL SD EN of
the Control Register is activated or
high. Bit 13 error can only be reset via
SRR or power-on reset.
H => Half Bridge 6 is active
L => Half Bridge 6 is in Hi-Z
H => Half Bridge 5 is active
L => Half Bridge 5 is in Hi-Z
SACT_
SACT_
HB3
HB9
9
9
SACT_
SACT_
HB2
HB8
8
8
26
SACT_
SACT_
HB1
HB7
7
7
SCONF
_HB6
6
6
X
SCONF
_HB5
5
5
X
Status Register - 1
HB 7:10
DESCRIPTION
Overcurrent Error is set if any one of
HB7 to HB10 has an overload, short
circuit or cross current; The error is
latched and the corresponding
output is switched off;
Bit 15 error can only be reset via
SRR or power-on reset.
Open Load Error is set if any one of
HB7 to HB10 has a true open load or
underload error condition; The error
is latched. The corresponding output
is switched off if Bit 13, OL SD EN of
the Control Register is activated or
high. Bit 13 error can only be reset
via SRR or power-on reset.
X => Don’t Care
X => Don’t Care
SCONF
SCONF
_HB10
_HB4
4
4
SCONF
SCONF
_HB3
_HB9
3
3
Deci Half Bridge IC
Rev. 1.0, 2010-04-27
SCONF
SCONF
_HB2
_HB8
2
2
TLE84110EL
SCONF
SCONF
_HB1
_HB7
1
1
TW
TW
0
0
SPI

Related parts for TLE84110EL