CX24118A-12Z,518 NXP Semiconductors, CX24118A-12Z,518 Datasheet - Page 31

no-image

CX24118A-12Z,518

Manufacturer Part Number
CX24118A-12Z,518
Description
IC SATELLITE TUNER DGTL 36HVQFN
Manufacturer
NXP Semiconductors
Type
Satellite Tunerr
Datasheet

Specifications of CX24118A-12Z,518

Package / Case
36-VQFN Exposed Pad, 36-HVQFN, 36-SQFN, 36-DHVQFN
Applications
Set-Top Boxes
Mounting Type
Surface Mount
Bus Type
I2C
Maximum Agc
90 dB (Typ)
Maximum Frequency
2175 MHz
Minimum Frequency
925 MHz
Mounting Style
SMD/SMT
Function
Satellite
Noise Figure
10 dB
Operating Supply Voltage
3.3 V
Supply Voltage (min)
3.13 V
Supply Voltage (max)
3.47 V
Minimum Operating Temperature
0 C
Maximum Operating Temperature
+ 70 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
935287217518
NXP Semiconductors
Register 12
Register 14
CX24118A_N_2
Product data sheet
CPLevel1[1:0]
CPLevel2[1:0]
CPLevel3[1:0]
CPLevel4[1:0]
BsDelayVal[3:0]
CPCtrl
CPVal[1:0]
Register
Register
Register
(Hex)
(Hex)
(Hex)
12
14
POR
POR
POR
80
00
Automatic Charge Pump Level 1 Select.
Charge pump level 1 is selected by the automatic tuning system when the VCO tuning voltage is greater than 2.0 V.
Automatic Charge Pump Level 2 Select.
Charge pump level 2 is selected by the automatic tuning system when the VCO tuning voltage is between 1.5 V and
Automatic Charge Pump Level 3 Select.
Charge pump level 3 is selected by the automatic tuning system when the VCO tuning voltage is between 1.0 V and
Automatic Charge Pump Level 4 Select.
Charge pump level 4 is selected by the automatic tuning system when the VCO tuning voltage is lower than 1.0 V.
For each of the above register fields, the analog charge pump levels are set as follows:
00b = 0.5 mA.
01b = 1.0 mA.
10b = 1.5 mA.
11b = 2.0 mA.
VCO Tuning System Delay.
VCO tuning system delay in reference clock cycles between the time tuning system is enabled and tuning starts. The
T
R is the reference divider value selected by register bit PLLRefDiv (0x02[1]).
Charge Pump Control.
0 = Analog charge pump turns OFF when the digital charge pump turns ON (when register bit TUNLD (0x10[1]) is
1 = Analog charge pump always ON. Use this setting for normal operation.
Analog Charge Pump Level.
This is the value selected by the automatic tuning system, as specified in register 0x11. The values correspond to the
00b = 0.5 mA.
01b = 1.0 mA.
10b = 1.5 mA.
11b = 2.0 mA.
For normal operation, set to 11b.
2.0 V.
For normal operation, set to 11b.
1.5 V.
For normal operation, set to 10b.
For normal operation, set to 00b.
default is 8 counts and can be set between 0 and 15 counts of reference cycle. The reference cycle period is:
For normal operation, set to 0x8.
low).
following charge pump levels. Read only.
D7
D7
REF
D7
TUNAutoEn[1:0]
= R/Reference oscillator frequency
D6
D6
D6
BsDelayVal[3:0]
Rev. 02 — 8 September 2009
D5
D5
D5
Chapter 3: Serial Programming Interface and Registers
D4
D4
D4
Reserved
D3
D3
D3
TUN1[5:0]
CPCtrl
D2
D2
D2
D1
D1
D1
CX24118A
CPVal[1:0]
© NXP B.V. 2009. All rights reserved.
D0
D0
D0
31