PSB 2134 H V2.2 Infineon Technologies, PSB 2134 H V2.2 Datasheet - Page 76

no-image

PSB 2134 H V2.2

Manufacturer Part Number
PSB 2134 H V2.2
Description
IC CODEC FILTER 4CHAN MQFP-64
Manufacturer
Infineon Technologies
Series
SICOFI®r
Datasheet

Specifications of PSB 2134 H V2.2

Function
CODEC Filter
Interface
IOM-2 PCM, SPI
Number Of Circuits
4
Voltage - Supply
5V
Current - Supply
26mA
Power (watts)
130mW
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
Level Metering Function, Tone Generation
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Other names
PSB2134HV2.2X
SP000007389
SP000007390
Semiconductor Group
The procedure to find an unknown level is predesigned to be carried out by software.
The first valid LMR-bit is available 4 ms after enabling the level metering via setting bit
LM. Then the LMR-bit is updated every 4 ms corresponding to the topical test signal and
the stored offset byte. During the measurement time of 4ms the test signal has to be
stable. That means for the above mentioned procedure to find an unknown level:
1. After programming the offset register and enabling the Level Metering Function, the
software has to wait for at least 4 ms before accessing the first valid LMR-bit.
2. After programming the offset register again the software has to wait for at least 4 ms
before accessing bit LMR.
3 After a change of the test level the software has to wait for at least 8 ms before
accessing bit LMR.
8.4
The bytes for the offset register are assigned to voltage values with a distance of about
0,02 Vrms. Since a level is measured by determining the bytes below and above, the
distance between two consecutive bytes defines the relative measuring precision.
The maximum relative measuring error is about 0.02 Vrms.
The absolute measuring precision is depending on the gain tracking and described in the
SICOFI2/4-TE data sheet.
8.5
In order to perform a measurement, an appropriate test signal is necessary.
There are 3 different ways to create a test signal: built-in tone generators, test equipment
PCM4 by Wandel and Goltermann or an external analog test source.
8.6
Only tone generator 1 is available for level metering. By setting the LM bit in CR2 tone
generator 2 is automatically switched off. But it is necessary to program both bandpass
filters with the same coefficients because the coefficients of tone generator 2 determine
also the bandpass filter for the Level Metering Function. Only with identically adjusted
bandpass filters a precise level metering is possible.
A very simplified block diagram is shown in figure 35.
Figure 32
Test signal generated by tone generator 1
Analog
Telephone
Set
Relative Measuring Precision
Generating Tests Signals
Tone Generators
Z
T
Subscriber
Line
Z
L
.
76
SLIC
Z
SLIC
Application Note: Level Metering
C
C
Test Signal
Tone Generator 1
Level Metering
Function
SICOFI2/4-TE
PSB 2132
PSB 2134
09.97