14.2.4 Immunity against mobile phones
14.3.1 Coupled
14.3 Transients - pulses (ISO 7637-1 and ISO 7637-3)
Test level: 200 V/m with C
State: A.
In deviation of ISO 11452-5 the measurement must be taken up to 1 GHz.
Tests according to ISO 11452-2 were fulfilled.
State: A.
Definition of Global System for Mobile Communications (GSM) signal:
In deviation of ISO 11452-2 a GSM signal (definition see above) instead of an AM signal
was used.
The KMA199E is designed for a stabilized 5 V supply. To raise immunity against
non-galvanic coupled transient pulses, protection diodes are implemented into the
KMA199E.
For applications with disturbances by capacitive or inductive coupling on supply line or
radiated disturbances an application circuit is recommended. Applications with this
arrangement passed the EMC tests according to the product standard 1 (electrical
transient transmission by capacitive or inductive coupling) and standard 3 (radiated
disturbances).
The common understanding of the requested function is that an effect is tolerated as
described in
reset or diagnostic mode and comes back after disturbances. If the KMA199E operates in
normal operation mode, the test pulses are visible on the signal line. A protection circuit is
used. The KMA199E is directly supplied with 5 V.
Table 25.
Tests according to ISO 7637-3 were fulfilled.
Level of pulses: IV ( 60 V for pulse 3a and +40 V for pulse 3b).
Class: B for pulse 3a, B for pulse 3b.
Parameter
Variation of output signal after exposure to
pulses in analog output mode
Pulse modulation: per GSM specification (217 Hz; 12.5 % duty cycle)
Modulation grade:
Sweep: linear 800 MHz to 3 GHz (duration 10 s at 890 MHz, 940 MHz and 1.8 GHz
band)
Antenna polarization: vertical, horizontal
Field strength: 200 V/m during on-time (calibration in CW)
Failure condition for transients
Table 25
Rev. 01 — 18 October 2007
during the disturbance. Class C means that the device goes into
60 dB
L
= 1 nF.
Comment
value measured relative to
the output at test start
Programmable angle sensor
KMA199E
Min
-
© NXP B.V. 2007. All rights reserved.
Max
0.9
Unit
%V