Specifications of KMA199E.115

Operating Temperature (min)
-40C
Operating Supply Voltage (typ)
5V
Lead Free Status / Rohs Status
Compliant
NXP Semiconductors
KMA199E_1
Product data sheet
13.3 Sending and receiving data
Figure 12
Here the pulse width t
T
For sending or receiving data, the master has to control the communication. The
command byte defines the region, address and type of command, which is requested by
the master, that is either a read or a write command. In case of a read command, an
additional handover or takeover bit respectively has to be inserted before and after the two
data bytes (see
Most Significant Byte (MSB) must be sent at first.
Table 14.
Table 15.
Bit
7 to 5
4 to 1
0
Fig 11. OWI start and stop condition
Fig 12. OWI timing
bit
CMD7
.
7
shows the coding of a single bit with a HIGH level of V
CMD[7:5]
CMD[4:1]
Symbol
CMD0
Format of a command byte
Command byte bit description
bit = 0
CMD6
6
Figure
0.175
t
w0
1
0.25
Rev. 01 — 18 October 2007
or t
10). However the OWI is a serial data transmission, whereas the
CMD5
0.375
Description
region bits
address bits
read/write
0
5
000 = 16-bit EEPROM
001 to 011 = reserved
100 = 16-bit register
101 to 111 = reserved
0 = write
1 = read
T
respectively represents a logic 1 or a logic 0 of a full bit period
t
bit
start
CMD4
4
bit = 1
CMD3
3
t
stop
t
w1
CMD2
Programmable angle sensor
T
2
001aag817
bit
0.625
IH
0.75
and a LOW level of V
0.825
KMA199E
CMD1
001aag818
© NXP B.V. 2007. All rights reserved.
1
CMD0
15 of 31
0
IL
.