M28W320FSU70ZA6 Micron Technology Inc, M28W320FSU70ZA6 Datasheet - Page 69

no-image

M28W320FSU70ZA6

Manufacturer Part Number
M28W320FSU70ZA6
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M28W320FSU70ZA6

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
21b
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TBGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
16b
Number Of Words
2M
Supply Current
18mA
Mounting
Surface Mount
Pin Count
64
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W320FSU70ZA6
Manufacturer:
ST
Quantity:
8 545
Part Number:
M28W320FSU70ZA6
Manufacturer:
ST
Quantity:
5 510
Part Number:
M28W320FSU70ZA6
Manufacturer:
ST
0
Part Number:
M28W320FSU70ZA6
Manufacturer:
ST
Quantity:
20 000
Part Number:
M28W320FSU70ZA6E
Manufacturer:
ST
0
Part Number:
M28W320FSU70ZA6F
Manufacturer:
ST
0
M28WxxxFS, M28WxxxFSU
Figure 22. Erase flowchart and pseudo code
1. If an error is found, the Status Register must be cleared before further Program/Erase operations.
Address & D0h
Read Status
Write Block
b4, b5 = 1
Write 20h
Register
b7 = 1
b3 = 0
b5 = 0
b1 = 0
Start
End
YES
YES
NO
YES
YES
NO
NO
YES
NO
NO
Sequence Error (1)
Erase to Protected
Erase Error (1)
Block Error (1)
V PP Invalid
Command
Error (1)
if ( (status_register.b5==1) )
/* erase error */
erase_command ( blockToErase ) {
if ( (status_register.b4==1) && (status_register.b5==1) )
/* command sequence error */
if (status_register.b1==1) /*program to protect block error */
if (status_register.b3==1) /*VPP invalid error */
}
do {
error_handler ( ) ;
error_handler ( ) ;
error_handler ( ) ;
error_handler ( ) ;
writeToFlash (any_address, 0x20) ;
writeToFlash (blockToErase, 0xD0) ;
/* only A12-A20 are significannt */
/* Memory enters read status state after
the Erase Command */
} while (status_register.b7== 0) ;
status_register=readFlash (any_address) ;
/* E or G must be toggled*/
Flowcharts and pseudo codes
AI03541b
69/76

Related parts for M28W320FSU70ZA6