MC33793DR2 Freescale Semiconductor, MC33793DR2 Datasheet - Page 18

IC DSI SLAVE FOR R-SENSE 16-SOIC

MC33793DR2

Manufacturer Part Number
MC33793DR2
Description
IC DSI SLAVE FOR R-SENSE 16-SOIC
Manufacturer
Freescale Semiconductor
Type
Distributed Systems Interfacer
Datasheet

Specifications of MC33793DR2

Input Type
Logic
Output Type
Logic
Interface
2 Line, I²C (CLK, Address/Data)
Mounting Type
Surface Mount
Package / Case
16-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Current - Supply
-
Lead Free Status / Rohs Status
Not Compliant
Other names
MC33793DR2TR
Table 17. I/O Control Response Format
REQUEST ID COMMAND
read from internal storage and returned to the master during
Table 18. Request ID Command Format
REQUEST ID RESPONSE
following a valid long-word Request ID command to the
Table 19. Request ID Response Format
CLEAR COMMAND
registers to the reset state. The command format is found in
Table
Table 20. Clear Command Format
READ/WRITE NVM COMMAND
command and the NVM has not been programmed
18
33793
FUNCTIONAL DEVICE OPERATION
DSI COMMANDS AND RESPONSES
Legend
A[3:0] = Address bits.
DR[3:0] = I/O enabled as outputs (1 = enabled as output).
Legend
A[3:0] = Address bits. The address of the selected device. An
address value of “0000” is ignored by all devices.
Legend
A[3:0] = Address bits. The slave address.
V[2:0] = Device version number. The silicon version number of the
device. For this device the device type is 00011 as indicated by the
lowest bits.
Legend
A[3:0] = Address bits. The address of the selected device. An
address value of “0000” clears all devices.
A3
A3
This command will cause the device ID information to be
This response message is sent during the next message
This command will open the bus switch and reset all
If the NV bit has been set by a previous Initialization
20. No response is generated for the Clear command.
A2
Address
A2
A1
A1
High Byte
A0
A0
Data
Data
0
0
0
Status
0
0
0
0
0
V2
L3
A3
A3
V1
L2
X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the
master.
X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the
master.
L[3:0] = Programmed values.
X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the
slave.
A2
A2
Address
Address
X[3:0] = Cyclic Redundancy Check (CRC). The CRC as calculated by the
slave.
L1
V0
the response to the next message. The command format is
found in
addressed device. The response format is found in
The high byte is omitted during the short-word response. No
response is generated if the command address field was $0.
previously, this command will permanently program the
device’s one-time programmable address and return the
programmed value during the next message time. Once
programmed, this nonvolatile address is used to set the
A1
A1
L0
Low Byte
Data
0
A0
A0
DR3
Table
0
0
0
DR2
18.
Command
Command
0
1
1
DR1
Analog Integrated Circuit Device Data
1
0
1
DR0
1
0
1
Freescale Semiconductor
X3
X3
X3
X3
X2
X2
X2
X2
CRC
CRC
CRC
CRC
X1
X1
X1
X1
Table
X0
X0
X0
X0
19.

Related parts for MC33793DR2