AMIS49587C5871RG ON Semiconductor, AMIS49587C5871RG Datasheet - Page 52

IC MODEM PLC 50/60MHZ 28PLCC

AMIS49587C5871RG

Manufacturer Part Number
AMIS49587C5871RG
Description
IC MODEM PLC 50/60MHZ 28PLCC
Manufacturer
ON Semiconductor
Datasheets

Specifications of AMIS49587C5871RG

Baud Rates
Selectable
Interface
SCI
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
28-PLCC
Number Of Transmitters
1
Power Supply Requirement
Single
Package Type
PLCC
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
28
Operating Temperature (max)
70C
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Format
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AMIS49587C5871RG
Manufacturer:
ON
Quantity:
3 400
Part Number:
AMIS49587C5871RG
Manufacturer:
ON Semiconductor
Quantity:
10 000
7.4.13.1 PhyAlarmRequest
Description:
This request is used to send a physical alarm pattern. No data is transmitted to indicate the number of repetitions, the
AMIS- -49587 already knows this number because it is in its set of configuration data.
Request Format:
Confirm Format:
7.4.14 AccessDB_Confirm
See paragraph AccessDB_Confirm.
7.4.15 AccessDB_Error
See paragraph AccessDB_Error.
7.5
*An unsolicited message is a message that is originating from the AMIS--49587, based upon an AMIS--49587 internal event. The message is
7.5.1 AccessDB_Request
The AccessDB_Request command can be used to read data path statistical information from the AMIS- -49587.
Like in all other AccessDB_Request commands, the specific identifier of the data that is to be read needs to be provided:
7.5.1.1 Invalid Frame Counter
Invalid Frame counter is automatically set to 0. The AMIS- -49587 answers with the value of the Invalid Frame Counter
Request Format:
Confirm Format:
Table 51. STATISTICS COMMAND AND RESPONSES
not provoked by a prior command sent by the external processor.
AccessDB_Request
AccessDB_Confirm
AccessDB_Error
Invalid--frame--counter
Counters
DataStats
<STX>
<STX>
<STX>
<STX>
This request is used to read the Invalid Frame Counter of the AMIS- -49587. Once the request sent to the AMIS- -49587, the
RETRIEVE STATISTICAL DATA FROM THE AMIS- -49587
Command
0x05(Length)
0x06(Length)
0x05(Length)
0x06(Length)
Field Name
0x42 (AccessDB_Confirm)
0x42 (AccessDB_Confirm)
Unsolicited*
no
no
no
Identifier
0x000D
0x0006
0x0010
Application micro controller
(DB_Data_Id)
AMIS--49587 (DB_Data_Id_Echo)
AMIS--49587 (Error_Code)
http://onsemi.com
0x41 (AccessDB_Request)
0x41 (AccessDB_Request)
Read the value of the invalid--frame counter and then set to 0
Read the value of the data counters:Counter Crc Ok, Counter Crc Not Ok,
Repeater counter, Transmit counter, corrected frames counter, and then
set to 0 or not
Read the value of the Data statistics, and then set to 0 or not.
52
Initiator
0x0600
0F00h
Number of alarm Transmissions (1 byte)
Invalid Frame Counter (1 byte)
Description
Master / Slave
Master / Slave
Master / Slave
Valid Command in Mode:
0x0F00
0x0600
Code
41h
42h
43h
CHK
CHK
CHK
CHK

Related parts for AMIS49587C5871RG