PIC18F2420-I/SP Microchip Technology Inc., PIC18F2420-I/SP Datasheet - Page 43

no-image

PIC18F2420-I/SP

Manufacturer Part Number
PIC18F2420-I/SP
Description
28 Pin, 16 KB Flash, 768 RAM, 25 I/O
Manufacturer
Microchip Technology Inc.
Datasheet

Specifications of PIC18F2420-I/SP

A/d Inputs
10-Channel, 10-Bit
Comparators
2
Cpu Speed
10 MIPS
Eeprom Memory
256 Bytes
Input Output
25
Interface
I2C/SPI/USART
Memory Type
Flash
Number Of Bits
8
Package Type
28-pin SPDIP
Programmable Memory
16K Bytes
Ram Size
768 Bytes
Speed
40 MHz
Timers
1-8-bit, 3-16-bit
Voltage, Range
2-5.5 V
Lead Free Status / Rohs Status
RoHS Compliant part Electrostatic Device

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F2420-I/SP
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
3.6.1
An adjustment may be indicated when the USART
begins to generate framing errors or receives data
with errors while in Asynchronous mode. Framing
errors indicate that the system clock frequency is too
high – try decrementing the value in the OSCTUNE
register to reduce the system clock frequency. Errors in
data may suggest that the system clock speed is too
low – increment OSCTUNE.
3.6.2
This technique compares system clock speed to some
reference clock. Two timers may be used; one timer is
clocked by the peripheral clock, while the other is
clocked by a fixed reference source, such as the
Timer1 oscillator.
Both timers are cleared but the timer clocked by the ref-
erence generates interrupts. When an interrupt occurs,
the internally clocked timer is read and both timers are
cleared. If the internally clocked timer value is greater
than expected, then the internal oscillator block is
running too fast – decrement OSCTUNE.
 2003 Microchip Technology Inc.
EXAMPLE – USART
EXAMPLE – TIMERS
PIC18F2220/2320/4220/4320
3.6.3
A CCP module can use free running Timer1 (or
Timer3), clocked by the internal oscillator block and an
external event with a known period (i.e., AC power fre-
quency). The time of the first event is captured in the
CCPRxH:CCPRxL registers and is recorded for use
later. When the second event causes a capture, the
time of the first event is subtracted from the time of the
second event. Since the period of the external event is
known, the time difference between events can be
calculated.
If the measured time is much greater than the
calculated time, the internal oscillator block is running
too fast – decrement OSCTUNE. If the measured time
is much less than the calculated time, the internal
oscillator block is running too slow – increment
OSCTUNE.
EXAMPLE – CCP IN CAPTURE
MODE
DS39599C-page 41

Related parts for PIC18F2420-I/SP