KU82596CA33 S N222 Intel, KU82596CA33 S N222 Datasheet - Page 30

no-image

KU82596CA33 S N222

Manufacturer Part Number
KU82596CA33 S N222
Description
Manufacturer
Intel
Datasheet

Specifications of KU82596CA33 S N222

Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
4.5V
Mounting
Surface Mount
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Not Compliant
Command Word
These bits specify the action to be performed as a result of a CA This word is set by the CPU and cleared by
the 82596 Defined bits are
Bit 31 ACK-CX
Bit 30 ACK-FR
Bit 29 ACK-CNA
Bit 28 ACK-RNR
Bits 24– 26 CUC
Bit 23 RESET
Bits 20– 22 RUC
31
ACK
Acknowledges that the CU completed an Action Command
Acknowledges that the RU received a frame
Acknowledges that the Command Unit became not active
Acknowledges that the Receive Unit became not ready
(3 bits) This field contains the command to the Command Unit Valid values are
0
1
2
3
4
5
6
7
Reset chip (logically the same as hardware RESET)
(3 bits) This field contains the command to the Receive Unit Valid values are
0
1
2
3
4
5 – 7
0
NOP (does not affect current state of the unit)
Start execution of the first command on the CBL If a command is executing
complete it before starting the new CBL The beginning of the CBL is in CBL
OFFSET (address)
Resume the operation of the Command Unit by executing the next command
This operation assumes that the Command Unit has been previously sus-
pended
Suspend execution of commands on CBL after current command is complete
Abort current command immediately
Loads the Bus Throttle timers so they will be initialized with their new values
after the active timer (T-ON or T-OFF) reaches Terminal Count If no timer is
active new values will be loaded immediately This command is not valid in
82586 mode
Loads and immediately restarts the Bus Throttle timers with their new values
This command is not valid in 82586 mode
Reserved
NOP (does not alter current state of unit)
Start reception of frames The beginning of the RFA is contained in the RFA
OFFSET (address) If a frame is being received complete reception before
starting
Resume frame reception (only when in suspended state)
Suspend frame reception If a frame is being received complete its reception
before suspending
Abort receiver operation immediately
Reserved
CUC
R
RUC
0
0
0
16
0
82596CA
SCB
a
2
29

Related parts for KU82596CA33 S N222