AD7195BCPZ Analog Devices Inc, AD7195BCPZ Datasheet - Page 19

IC AFE 24BIT 4.8K 32LFSP

AD7195BCPZ

Manufacturer Part Number
AD7195BCPZ
Description
IC AFE 24BIT 4.8K 32LFSP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7195BCPZ

Design Resources
Precision Weigh Scale Design Using AD7195 with Internal PGA and AC Excitation (CN0155)
Number Of Bits
24
Number Of Channels
4
Voltage - Supply, Analog
4.75 V ~ 5.25 V
Voltage - Supply, Digital
2.7 V ~ 5.25 V
Package / Case
32-LFCSP
Resolution (bits)
24bit
Sampling Rate
4.8kSPS
Input Channel Type
Pseudo Differential
Data Interface
3-Wire, Serial
Supply Voltage Range - Analog
4.75V To 5.25V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7195BCPZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD7195BCPZ
Manufacturer:
TST
Quantity:
5 000
Part Number:
AD7195BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7195BCPZ-RL
Manufacturer:
SEMTECH
Quantity:
394
STATUS REGISTER
(RS2, RS1, RS0 = 0, 0, 0; Power-On/Reset = 0x80)
The status register is an 8-bit read-only register. To access the ADC status register, the user must write to the communications register,
select the next operation to be a read, and load Bit RS2, Bit RS1, and Bit RS0 with 0. Table 21 outlines the bit designations for the status
register. SR0 through SR7 indicate the bit locations, SR denoting that the bits are in the status register. SR7 denotes the first bit of the data
stream. The number in parentheses indicates the power-on/reset default status of that bit.
SR7
RDY(1)
Table 21. Status Register Bit Designations
Bit Location
SR7
SR6
SR5
SR4
SR3
SR2 to SR0
MODE REGISTER
(RS2, RS1, RS0 = 0, 0, 1; Power-On/Reset = 0x080060)
The mode register is a 24-bit register from which data can be read or to which data can be written. This register is used to select the
operating mode, the output data rate, and the clock source. Table 22 outlines the bit designations for the mode register. MR0 through
MR23 indicate the bit locations, MR denoting that the bits are in the mode register. MR23 denotes the first bit of the data stream. The
number in parentheses indicates the power-on/reset default status of that bit. Any write to the mode register resets the modulator and
filter and sets the RDY bit.
MR23
MD2(0)
MR15
SINC3(0)
MR7
FS7(0)
0
Bit Name
RDY
ERR
NOREF
PARITY
CHD2 to
CHD0
SR6
ERR(0)
MR22
MD1(0)
MR14
0
MR6
FS6(1)
Description
Ready bit for the ADC. This bit is cleared when data is written to the ADC data register. The RDY bit is set
automatically after the ADC data register is read, or a period of time before the data register is updated,
with a new conversion result to indicate to the user that the conversion data should not be read. It is also
set when the part is placed in power-down mode or idle mode or when SYNC is taken low. The end of a
conversion is also indicated by the DOUT/RDY pin. This pin can be used as an alternative to the status
register for monitoring the ADC for conversion data.
ADC error bit. This bit is written to at the same time as the RDY bit. This bit is set to indicate that the result
written to the ADC data register is clamped to all 0s or all 1s. Error sources include overrange or under-
range, or the absence of a reference voltage. This bit is cleared when the result written to the data register
is within the allowed analog input range again.
No external reference bit. This bit is set to indicate that the reference is at a voltage that is below a specified
threshold. When set, conversion results are clamped to all 1s. This bit is cleared to indicate that a valid
reference is applied to the selected reference pins. The NOREF bit is enabled by setting the REFDET bit in
the configuration register to 1.
Parity check of the data register. If the ENPAR bit in the mode register is set, the PARITY bit is set if there is
an odd number of 1s in the data register. It is cleared if there is an even number of 1s in the data register.
The DAT_STA bit in the mode register should be set when the parity check is used. When the DAT_STA bit is
set, the contents of the status register are transmitted along with the data for each data register read.
This bit is set to 0.
These bits indicate which channel corresponds to the data register contents. They do not indicate which
channel is presently being converted but indicate which channel was selected when the conversion
contained in the data register was generated.
SR5
NOREF(0)
MR21
MD0(0)
MR13
ENPAR(0)
MR5
FS5(1)
SR4
PARITY(0)
MR20
DAT_STA(0)
MR12
0
MR4
FS4(0)
Rev. 0 | Page 19 of 44
SR3
0
MR19
CLK1(1)
MR11
SINGLE(0)
MR3
FS3(0)
SR2
CHD2(0)
MR18
CLK0(0)
MR10
REJ60(0)
MR2
FS2(0)
SR1
CHD1(0)
MR17
0
MR9
FS9(0)
MR1
FS1(0)
SR0
CHD0(0)
MR16
0
MR8
FS8(0)
MR0
FS0(0)
AD7195

Related parts for AD7195BCPZ