5962-8981703XA QP SEMICONDUCTOR, 5962-8981703XA Datasheet - Page 12

no-image

5962-8981703XA

Manufacturer Part Number
5962-8981703XA
Description
Manufacturer
QP SEMICONDUCTOR
Datasheet

Specifications of 5962-8981703XA

Organization
32Kx8
Interface Type
Parallel
In System Programmable
In System/External
Access Time (max)
35ns
Package Type
CDIP
Reprogramming Technique
UV
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Supply Current
130mA
Pin Count
28
Mounting
Through Hole
Operating Temp Range
-55C to 125C
Operating Temperature Classification
Military
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8981703XA
Quantity:
13
Part Number:
5962-8981703XA
Manufacturer:
UC
Quantity:
650
Part Number:
5962-8981703XA
Manufacturer:
CYP
Quantity:
149
Part Number:
5962-8981703XA
Manufacturer:
E2V
Quantity:
20 000
DSCC FORM 2234
APR 97
(original equipment), design applications, and logistics purposes.
prepared specification or drawing.
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
application requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be
used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC
5962) should contact DSCC-VA, telephone (614) 692-0544.
(614) 692-0547.
HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted
by DSCC-VA
4.5 Programming procedures. The programming procedures shall be as specified by the device manufacturer.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43218-3990, or telephone
6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-
.
DEFENSE SUPPLY CENTER COLUMBUS
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43218-3990
STANDARD
1/ * indicates PDA applies to subgroups 1 and 7.
2/ Any or all subgroups may be combined when using high-speed testers.
3/ ** see 4.3.1c.
Interim electrical parameters
Final electrical test parameters
(method 5004) for unprogrammed
devices
Final electrical test parameters
(method 5004) for programmed
devices
Group A test requirements
Groups C and D end-point electrical
parameters (method 5005)
(method 5004)
(method 5005)
MIL-STD-883 test requirements
TABLE II. Electrical test requirements.
SIZE
A
1*, 2, 3, 7*, 8A, 8B, 9
(in accordance with
1*, 2, 3, 7*, 8A, 8B
1,2,3,4**,7,8A,8B,
2, 3, 7, 8A, 8B
MIL-STD-883,
Subgroups
TM 5005, table I)
9, 10,11
1/ 2/ 3/
REVISION LEVEL
1
C
SHEET
5962-89817
12

Related parts for 5962-8981703XA