Specifications of LAN9215-MT

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
100
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9215-MT
Manufacturer:
BROADCOM
Quantity:
450
Part Number:
LAN9215-MT
Manufacturer:
Standard
Quantity:
1 643
Part Number:
LAN9215-MT
Manufacturer:
SMSC
Quantity:
9
Part Number:
LAN9215-MT
Manufacturer:
SMSC
Quantity:
8 000
Part Number:
LAN9215-MT
Manufacturer:
SMSC
Quantity:
20 000
Revision 2.7 (03-15-10)
3.8.2.2
3.8.2.3
3.8.2.4
3.9
3.9.1
3.9.2
MAC Address Reload
The MAC address can be reloaded from the EEPROM via a host command to the E2P_CMD register.
If a value of 0xA5h is not found in the first address of the EEPROM, the EEPROM is assumed to be
un-programmed and MAC Address Reload operation will fail. The “MAC Address Loaded” bit indicates
a successful load of the MAC address. The EPC_LOAD bit is set after a successful reload of the MAC
address.
EEPROM Command and Data Registers
Refer to
"E2P_DATA – EEPROM Data Register," on page 100
Supported EEPROM operations are described in these sections.
EEPROM Timing
Refer to
The LAN9215 supports power-down modes to allow applications to minimize power consumption. The
following sections describe these modes.
System Description
Power is reduced to various modules by disabling the clocks as outlined in Table 3.9, “Power
Management States,” on page 42. All configuration data is saved when in either of the two low power
states. Register contents are not affected unless specifically indicated in the register description.
Functional Description
There is one normal operating power state, D0 and there are two power saving states: D1, and D2.
Upon entry into either of the two power saving states, only the PMT_CTRL register is accessible for
read operations. In either of the power saving states the READY bit in the PMT_CTRL register will be
cleared. Reads of any other addresses are forbidden until the READY bit is set. All writes, with the
exception of the wakeup write to BYTE_TEST, are also forbidden until the READY bit is set. Only when
in the D0 (Normal) state, when the READY bit is set, can the rest of the device be accessed.
Power Management
OPERATION
ERASE
WRITE
EWDS
EWEN
WRAL
READ
ERAL
Section 5.3.23, "E2P_CMD – EEPROM Command Register," on page 98
Section 6.9, "EEPROM Timing," on page 131
Table 3.8 Required EECLK Cycles
DATASHEET
40
REQUIRED EECLK CYCLES
for detailed EEPROM timing specifications.
16-bit Non-PCI 10/100 Ethernet Controller with HP Auto-MDIX Support
for a detailed description of these registers.
10
10
10
10
18
18
18
and
Section 5.3.24,
SMSC LAN9215
Datasheet