STA328 STMicroelectronics, STA328 Datasheet - Page 22

no-image

STA328

Manufacturer Part Number
STA328
Description
DIG AUDIO SYSTEM, 2-CH, 36POWERSSOP
Manufacturer
STMicroelectronics
Datasheet

Specifications of STA328

Svhc
No SVHC (15-Dec-2010)
Package / Case
PowerSO
Interface
I2C
No. Of Pins
36
Operating Temperature Range
-20°C To +125°C
Supply Voltage Max
36V
Supply Voltage Min
10V
Termination
RoHS Compliant
Interface Type
I2C
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STA328
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA328 VJ
Manufacturer:
ST
0
Part Number:
STA328-2LF/
Manufacturer:
ST
0
Part Number:
STA328VJ
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA328VT
Manufacturer:
ST
Quantity:
20 000
Register description
22/57
Table 15.
The on-chip STA328 power output block provides feedback to the digital controller using
inputs to the power control block. The TWARN input is used to indicate a thermal warning
condition. When TWARN is asserted (set to 0) for a period greater than 400 ms, the power
control block will force an adjustment to the modulation limit in an attempt to eliminate the
thermal warning condition. Once the thermal warning volume adjustment is applied,
whether the gain is reapplied when TWARN is de-asserted is dependent on the TWRB bit.
Table 16.
The DDX
power control block. The FAULT input is used to indicate a fault condition (either over-current
or thermal). When FAULT is asserted (set to 0), the power control block will attempt a
recovery from the fault by asserting the 3-state output (setting it to 0 which directs the power
output block to begin recovery). It holds it at 0 for period of time in the range of 0.1 ms to 1 s
as defined by the fault-detect recovery constant register (FDRC registers 0x29 to 0x2A),
then toggle it back to 1. This sequence is repeated as log as the fault indication exists. This
feature is enabled by default but can be bypassed by setting the FDRB control bit to 1.
6
7
Bit
Bit
RW
RW
R/W
R/W
®
power block can provide feedback to the digital controller using inputs to the
Thermal warning adjustment bypass
Fault detect recovery bypass
1
0
RST
RST
TWAB
FDRB
Name
Name
Thermal warning adjustment bypass:
0: thermal warning adjustment enabled
1: thermal warning adjustment disabled
Fault detector recovery bypass:
0: fault detector recovery enabled
1: fault detector recovery disabled
Description
Description
STA328

Related parts for STA328