OKL-T/6-W5P-C Murata Power Solutions Inc, OKL-T/6-W5P-C Datasheet - Page 17

DC/DC Converters & Regulators 5Vin 0.6-3.3Vout 6A 19.8W Pos Polarity

OKL-T/6-W5P-C

Manufacturer Part Number
OKL-T/6-W5P-C
Description
DC/DC Converters & Regulators 5Vin 0.6-3.3Vout 6A 19.8W Pos Polarity
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of OKL-T/6-W5P-C

Output Power
19.8 W
Input Voltage Range
2.4 V to 5.5 V
Input Voltage (nominal)
5 V
Number Of Outputs
1
Package / Case Size
12.2 mm x 12.2 mm x7.2 mm
Output Voltage
0.6 V to 3.3 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage Range Graph
Please observe the limits below for voltage input and output ranges. These
limits apply at all output currents.
6
5
4
3
2
1
0
0.5
Vin=2.4V / Vout=1.8V
1
1.5
Output Voltage (V)
2
2.5
3
Upper Limit
Lower Limit
www.murata-ps.com
3.5
Soldering Guidelines
Murata Power Solutions recommends the specifi cations below when installing these
converters. These specifi cations vary depending on the solder type. Exceeding these
specifi cations may cause damage to the product. Your production environment may differ
therefore please thoroughly review these guidelines with your process engineers.
Recommended Lead-free Solder Refl ow Profi le
250
200
150
100
50
0
0
Programmable Output 6-Amp iLGA SMT PoLs
For Sn/Ag/Cu based solders:
Preheat Temperature
Time over Liquidus
Maximum Peak Temperature
Cooling Rate
For Sn/Pb based solders:
Preheat Temperature
Time over Liquidus
Maximum Peak Temperature
Cooling Rate
Reflow Solder Operations for surface-mount products (SMT)
30
<1.5° C/sec
60
09 May 2011 MDC_OKL-T/6-W5 Series.A08 Page 17 of 18
90
OKL-T/6-W5 Series
Preheating Zone
240 sec max
Soaking Zone
120
Peak Temp.
120 sec max
235-260° C
Time (sec)
Less than 1 ºC. per second
45 to 75 seconds
260 ºC.
Less than 3 ºC. per second
Less than 1 ºC. per second
60 to 75 seconds
235 ºC.
Less than 3 ºC. per second
150
180
email: sales@murata-ps.com
time above 217° C
Reflow Zone
45-75 sec
210
High trace = normal upper limit
Low trace = normal lower limit
240
270
300

Related parts for OKL-T/6-W5P-C