MT5634ZBA-GLOBAL Multi-Tech Systems, MT5634ZBA-GLOBAL Datasheet - Page 33

no-image

MT5634ZBA-GLOBAL

Manufacturer Part Number
MT5634ZBA-GLOBAL
Description
MODEM V.90 DATA/FAX GLOBAL
Manufacturer
Multi-Tech Systems
Series
MultiModem® ZBAr

Specifications of MT5634ZBA-GLOBAL

Data Format
V.90
Mounting Type
Desktop
Package / Case
5.7" L x 4.3" W x 1.0" H (145mm x 109mm x 25mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Supply
-
Interface
-
Other names
881-1149
MT5634ZBA-GLOBAL
$MB
Description:
Syntax:
Default:
Values:
$RP
Description:
Syntax:
Values:
Reports:
$SB
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
Online BPS Speed
Selects speed in bits per second.
AT$MB<value>
28,800
75
300
1200
2400
4800
9600
14400
19200
28800
33600
Ring Priority vs. AT Command Priority
Sets the ring priority vs. the AT command priority.
Note:
AT$RP<value>
0
1
Note:
simulators as a valid ring
$RP?
Serial Port Baud Rate
Sets the serial port baud rate.
Note:
AT$SB<value>
$SB300
$SB1200
$SB2400
$SB4800
$SB9600
$SB19200
$SB38400
$SB57600
$SB115200
$SB230400
This command does not work with parallel, USB, PCI, PCIe.
This command does not work with parallel, USB, PCI, PCIe.
Displays the current value (0 or 1)
The AT command will have priority over the ring. S1 will be reset to 0 if an AT
command is received. This command is storable to memory.
The ring will have priority over the AT command. S1 will increment even if an
AT command and ring are received together and the incoming call will be
answered when S1 is equal to S0. Default.
SocketModems do not detect ring cadence of TelTone telephone line
Selects CCITT V.23 mode
Selects 300 bps on-line
Selects 1200 bps on-line
Selects 2400 bps on-line
Selects 4800 bps on-line
Selects 9600 bps on-line
Selects 14400 bps on-line
Selects 19200 bps on-line
Selects 28800 bps on-line
Selects 33600 bps on-line
Sets serial port to 300 bps
Sets serial port to 1200 bps
Sets serial port to 2400 bps
Sets serial port to 4800 bps
Sets serial port to 9600 bps
Sets serial port to 19200 bps
Sets serial port to 38400 bps
Sets serial port to 57600 bps (Default)
Sets serial port to 115200 bps
Sets serial port to 230400 bps
Chapter 1 – AT Commands, S-Registers, and Result Codes
33