71M6511H-IGT/F Maxim Integrated Products, 71M6511H-IGT/F Datasheet - Page 72

IC ENERGY METER RESIDENT 64-LQFP

71M6511H-IGT/F

Manufacturer Part Number
71M6511H-IGT/F
Description
IC ENERGY METER RESIDENT 64-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 71M6511H-IGT/F

Processor Series
6511x
Core
80515
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
64 KB
Data Ram Size
7 KB
Interface Type
I2C, SSI, UART
Maximum Clock Frequency
5 MHz
Number Of Programmable I/os
12
Number Of Timers
2
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
LQFP-64
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
71M6511H-DB
Minimum Operating Temperature
- 40 C
On-chip Adc
22 bit Delta Sigma
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6511H-IGT/F
Manufacturer:
PERICOM
Quantity:
1 200
Part Number:
71M6511H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Page: 72 of 98
Address
0x2D
0x3C
0x28
0x29
0x36
0x37
0x26
0x27
CE
A Maxim Integrated Products Brand
PULSE_WIDTH
PULSE_SLOW
PULSE_FAST
EXT_PULSE
SUM_PRE
APULSEW
APULSER
WRATE
Name
Default
1556
2520
15
50
1
1
0
0
© 2005–2010 Teridian Semiconductor Corporation
Description
When PULSE_SLOW > 0, the pulse generator input is reduced 64x.
When PULSE_FAST > 0, the pulse generator input is increased 16x.
These two parameters control the pulse gain factor X (see table below).
Allowed values are either 1 or –1.
Kh =
VMAX*IMAX*47.1132 / (In_8*WRATE*N
VMAX*IMAX*36.2409 / (In_8*WRATE*N
PRE_SAMPS * SUM_CYCLES. This variable is also called N
Should be 15 or 0. When zero, causes the pulse generators to respond to
WSUM_X and VARSUM_X. Otherwise, the generators respond to values the
MPU places in APULSEW and APULSER.
The maximum pulse width (low-going pulse) is:
(2 * PULSE_WIDTH + 1) * 397µs (for MUX_DIV = 1)
(2 * PULSE_WIDTH + 1) * 305µs (for MUX_DIV = 2)
0 is a legitimate value.
Wh pulse generator input, to be updated by the MPU when using external pulse
generation (see DIO_PW bit). The output pulse rate is:
APULSEW * F
This input is buffered and can be updated by the MPU during a computation in-
terval. The change will take effect at the beginning of the next interval.
VARh pulse generator input to be updated by the MPU when using external
pulse generation (see DIO_PV bit). The output pulse rate is:
APULSER * F
This input is buffered and can be updated by the MPU during a computation in-
terval. The change will take effect at the beginning of the next interval.
X
1.5 * 2
1.5 * 2
1.5 * 2
1.5
2
6
-4
S
S
*2
= 6
= 96
= 0.09375
* 2
-32
-32
* WRATE * 2
Single-Phase Energy Meter IC
* WRATE * 2
71M6511/71M6511H
PULSE_SLOW
-1
-1
1
1 (default)
-14
-14
DATA SHEET
ACC
ACC
*X) Wh/pulse (for MUX_DIV = 1).
*X) Wh/pulse (for MUX_DIV = 2).
PULSE_FAST
-1
1
-1
1 (default)
ACC
NOVEMBER 2010
.
V2.7