ATTINY261V-10MU Atmel, ATTINY261V-10MU Datasheet - Page 186

IC MCU AVR 2K FLASH 10MHZ 32-QFN

ATTINY261V-10MU

Manufacturer Part Number
ATTINY261V-10MU
Description
IC MCU AVR 2K FLASH 10MHZ 32-QFN
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheet

Specifications of ATTINY261V-10MU

Core Processor
AVR
Core Size
8-Bit
Speed
10MHz
Connectivity
USI
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
2KB (1K x 16)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Processor Series
ATTINY2x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
128 B
Interface Type
2-Wire, SPI, USI
Maximum Clock Frequency
10 MHz
Number Of Programmable I/os
16
Number Of Timers
2
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 11 Channel
For Use With
ATSTK600 - DEV KIT FOR AVR/AVR32ATAVRBC100 - REF DESIGN KIT BATTERY CHARGER770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAGATSTK505 - ADAPTER KIT FOR 14PIN AVR MCU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY261V-10MU
Manufacturer:
Atmel
Quantity:
1 962
Company:
Part Number:
ATTINY261V-10MU
Quantity:
496
18.7.14
18.7.15
186
ATtiny261/461/861
Reading the Signature Bytes
Reading the Calibration Byte
Figure 18-8. Mapping Between BS1, BS2 and the Fuse and Lock Bits During Read
The algorithm for reading the Signature bytes is as follows (refer to
page 180
The algorithm for reading the Calibration byte is as follows (refer to
page 180
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte (0x00 - 0x02).
3. Set OE to “0”, and BS to “0”. The selected Signature byte can now be read at DATA.
4. Set OE to “1”.
1. A: Load Command “0000 1000”.
2. B: Load Address Low Byte, 0x00.
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.
4. Set OE to “1”.
Fuse Low Byte
Extended Fuse Byte
Fuse High Byte
Lock Bits
for details on Command and Address loading):
for details on Command and Address loading):
BS2
BS2
0
1
0
1
BS1
“Programming the Flash” on
“Programming the Flash” on
0
1
2588E–AVR–08/10
DATA

Related parts for ATTINY261V-10MU