VPP24-2330 Triad Magnetics, VPP24-2330 Datasheet - Page 2

TRANSF 12VAC 4.66A WORLD SERIES

VPP24-2330

Manufacturer Part Number
VPP24-2330
Description
TRANSF 12VAC 4.66A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP24-2330

Maximum Power
56 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
24 VAC @ 2.33A
Parallel Output Voltage @ Current
12 VAC @ 4.66A
Mounting Type
Through Hole
Power Rating
56 VA
Product
World Series Transformers
Brand/series
World Series™/VPP Series
Configuration
Bobbin
Current, Secondary
4.66/2.33 A
Dielectric Strength
4000 V (RMS)
Dimensions
3"W×1-13/16"H×2-1/2"D
Frequency
50/60 Hz
Number Of Outlets
2
Phase
1
Power, Rating
56 VA
Standards
UL, CSA, VDE
Temperature, Operating
+30 °C
Termination
Thru-Hole
Voltage, Primary
115/230 VAC
Voltage, Secondary
12/24 VAC
Weight
1.7 lbs.
Mounting Style
SMD/SMT
Height
1.812 in
Length
2.5 in
Termination Style
Solder
Width
3 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
24V
Current Rating
4.66A
Transformer Mounting
PC Board
Secondary Current Nom
4.66A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 12V
Output Current
4.66A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10505
237-1092
: :
www.TriadMagnetics.com
T e c h n i c a l N o t e s
1. Hi-pot tested at 4,000 VRMS.
2. Both primary and secondary coils may
O u t l i n e D i m e n s i o n s
be connected as either series or parallel,
but both must be used simultaneously.
The Sales, Service and Technical professionals at Triad Magnetics have over 100
years combined experience in the magnetics industry. This translates to solutions
you can count on for your power, switching and filtering applications.
|
22520 B Temescal Canyon Road, Corona, CA 92883
|
Phone 951-277-0757
|
FAX 951-277-2757