LOCATOR PLATE PLUG

3443-96

Manufacturer Part Number
3443-96
Description
LOCATOR PLATE PLUG
Manufacturer
3M
Datasheets

Specifications of 3443-96

Features
Optional strain relief and pull tab
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
0-00-54007-35784-1
00054007357841
05400735784
3443-96
344396
3M9432
5400735784
54007357841
80-6101-7285-2
80-610172852
80610172852
3.5
3.6
4.0
4.1
4.2
Rotate the shut height to lower or raise
adjustment feature until the bottom of the shaft
contacts the desired position on the shut height
gauge. (Figure 3 and 4)
Install the locator plate and the appropriate
platen on the press. The platen should be
positioned parallel with the connector body
and cover.
Procedures for Connector/Cable Assembly
Grasp a plug cover strip between thumb and
forefinger of both hands, with the liner facing
you. Rotate the outermost cover down against
the adjacent cover on the strip, breaking it
from the liner. Pull laterally away from the
strip. Adhesive should be present on the cover.
(Figure 5)
Firmly press ribbed side of cable into the
alignment grooves on cover. The adhesive will
help it to stay in place. Visually inspect to
ensure that:
a. Cable is properly aligned to cover grooves.
b. Cable end is flush with the cover for end
terminations or perpendicular to cover for
midspan terminations. (Figure 6)
4
Figure 3
Figure 4
Figure 5
Figure 6
- Press 3640
- Press 3335