69912 Tyco Electronics, 69912 Datasheet
![no-image](/images/manufacturer_photos/0/6/687/tyco_electronics_sml.jpg)
69912
Specifications of 69912
69912 Summary of contents
Page 1
... Figure 1 This instruction sheet covers the use and maintenance of Crimping Die Assemblies 69911, 69912, 69913, and 69914, which are used in the DYNA–CRIMP Crimping Head 69082. Terminal D When using two or more wires, the combined cross sectional area must be within the circular mil range listed. ...
Page 2
... Crimping Die Assemblies 69911, 69912, 69913, and 69914 2. Select the correct dies for the wire size being used. See Figure 2. 3. Loosen locking screw in top section of crimping head. See Figure 1. 4. Insert shank of stationary die into top section of crimping head and tighten locking screw. ...
Page 3
... Crimping Die Assemblies 69911, 69912, 69913, and 69914 Terminal ACCEPT Parallel Splice 5. CRIMP INSPECTION Inspect crimped terminals and splices by checking the features described in Figure 4. Use only the terminals and splices that meet the conditions shown in the “ACCEPT” column. “REJECT” terminals and splices ...
Page 4
... Crimping Die Assemblies 69911, 69912, 69913, and 69914 however, amount of use, working conditions, operator training and skill, and established company standards should determine frequency of inspection. The inspection should be performed in the following sequence: A. Visual Inspection 1. Remove all lubrication and accumulated film by immersing the dies in a suitable commercial degreaser that will not affect paint or plastic material ...
Page 5
Die Closure Configuration Figure 7 Figure 6 Figure 8 ...