B. Gaging the Crimping Chamber
An inspection should be performed periodically to
check the jaw closure for excessive wear. The jaw
closure inspection is accomplished using plug gages.
Tyco Electronics neither manufacturers nor sells plug
D
4
Pneumatic TETRA-CRIMP Adapter 679305-1
ITEM
3. Inspect the crimping area for flattened, chipped,
or broken areas. Although the crimping chambers
may gage within permissible limits, worn or
damaged jaw closure surfaces are objectionable
and will affect the quality of the crimp.
PART NO.
DESCRIPTION
REPLACEMENT PARTS
ADAPTER
QTY PER
Figure 5
gages. A suggested plug gage design and
dimensions of the plug gage GO and NO–GO
elements are listed in Figure 6. The following
procedure is recommended for inspecting the
crimping chambers.
ITEM
1. DISCONNECT AIR SUPPLY and remove
adapter from tool holder. Refer to Section 3,
ADAPTER INSTALLATION AND REMOVAL.
2. Remove oil and dirt from the jaw surfaces, jaw
closure surfaces, and plug gage element surfaces.
PART NO.