FLUKE-568 Fluke Electronics, FLUKE-568 Datasheet - Page 13

THERMOMETER IR W/PROBE MENU& MEM

FLUKE-568

Manufacturer Part Number
FLUKE-568
Description
THERMOMETER IR W/PROBE MENU& MEM
Manufacturer
Fluke Electronics
Series
568r
Type
Handheld, Gunr
Datasheet

Specifications of FLUKE-568

Temperature Range
-40 ~ 1472°F (-40 ~ 800°C)
Temperature Display
C°/F°
Display Type
Dot Matrix
Input Type
Infrared; Thermocouple
Features
Alarm, Backlight, Laser Sight, Memory, MIN/MAX/Dif/Avg
Probe Type
K
Battery Type
AA (2)
Includes
Case, Software, Thermocouple - K-Type Bead Probe, USB Cable
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
2837806
614-1073
Menu Overview
Save
Level
1
2
3
4
5
6
There are many settings that can be easily changed by using the menu. Figure 2 shows
the LCD and menu interface. Selecting the Menu softkey advances the menu to the next
level. Table 2 is a top-level description of the menu.
Each menu item and function is explained in greater detail in the following sections.
To save readings:
1. Pull the trigger to take a measurement.
2. Release the trigger to stop taking the measurement.
3. Press the Save softkey to enter the Save menu.
4. Press the Yes softkey to save the reading.
The reading is assigned a memory location and a time and date stamp.
Softkey
Save
Mem
MnMx
°C/°F
Setup
(Lock)
Left
G
Save reading to memory
Review/delete memories
Enables Min/Max
Toggle between C and F
Lock the thermometer on
- Turn off/on backlight
- Change Time/Date
- Change Language
Description
Table 2. Top-Level Menu Description
Figure 2. Menu Navigation
Menu
Menu
Menu
Menu
Menu
Menu
Softkey
Center
Softkey
Light
ε
Avg
Alarm
Laser
-
Right
Adjust backlight
brightness
Set emissivity
Enable Avg/Diff
Set and enable alarms
Toggle the laser on/off
-
Description
Infrared Thermometers
eyl01.eps
Menu Overview
5