FLUKE-568 Fluke Electronics, FLUKE-568 Datasheet

THERMOMETER IR W/PROBE MENU& MEM

FLUKE-568

Manufacturer Part Number
FLUKE-568
Description
THERMOMETER IR W/PROBE MENU& MEM
Manufacturer
Fluke Electronics
Series
568r
Type
Handheld, Gunr
Datasheet

Specifications of FLUKE-568

Temperature Range
-40 ~ 1472°F (-40 ~ 800°C)
Temperature Display
C°/F°
Display Type
Dot Matrix
Input Type
Infrared; Thermocouple
Features
Alarm, Backlight, Laser Sight, Memory, MIN/MAX/Dif/Avg
Probe Type
K
Battery Type
AA (2)
Includes
Case, Software, Thermocouple - K-Type Bead Probe, USB Cable
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
2837806
614-1073
®
566/568
Infrared Thermometers
Users Manual
August 2007 Rev. 2, 4/08
© 2007-2008 Fluke Corporation, All rights reserved. Product specifications are subject to change without notice.
All product names are trademarks of their respective companies.

FLUKE-568 Summary of contents

Page 1

... August 2007 Rev. 2, 4/08 © 2007-2008 Fluke Corporation, All rights reserved. Product specifications are subject to change without notice. All product names are trademarks of their respective companies. 566/568 Infrared Thermometers Users Manual ® ...

Page 2

... Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price ...

Page 3

... Introduction........................................................................................................ 1 Contacting Fluke................................................................................................ 1 Safety Information ............................................................................................. 2 Symbols and Markings ...................................................................................... 3 Features.............................................................................................................. 4 Display Language .............................................................................................. 4 Menu Overview ................................................................................................. 5 Save ............................................................................................................... 5 Light .............................................................................................................. 6 Memory ......................................................................................................... 6 Emissivity Menu............................................................................................ 6 C and F ....................................................................................................... 7 Min, Max, Avg, Differential.......................................................................... 7 Alarm............................................................................................................. 8 Trigger Lock.................................................................................................. 8 Laser .............................................................................................................. 8 Setup .............................................................................................................. 9 Backlight ................................................................................................... 9 Time/Date.................................................................................................. 9 Language ................................................................................................... 10 Deleting Data................................................................................................. 10 Deleting All Data ...................................................................................... 10 Deleting Individual Data Records ............................................................. 10 How the Thermometers Work ...

Page 4

Users Manual Maintenance....................................................................................................... 17 Battery Charge............................................................................................... 17 Changing the Batteries .................................................................................. 17 Cleaning the Lens .......................................................................................... 18 Cleaning the Housing .................................................................................... 18 User Replaceable Parts and Accessories............................................................ 18 User Replaceable Parts .................................................................................. 18 Accessories .................................................................................................... 18 Recommended Temperature Probes.............................................................. 19 ...

Page 5

Table 1. Symbols.................................................................................................................. 3 2. Top-Level Menu Description ................................................................................. 5 3. Nominal Surface Emissivity................................................................................... 7 4. Troubleshooting ..................................................................................................... 16 5. Replaceable Parts ................................................................................................... 18 6. Recommended Temperature Probes....................................................................... 19 List of Tables Title iii Page ...

Page 6

Users Manual iv ...

Page 7

Figure 1. Laser Safety Markings ........................................................................................... 3 2. Menu Navigation.................................................................................................... 5 3. How the Thermometer Works................................................................................ 11 4. Locating a Hot or Cold Spot .................................................................................. 12 5. Distance and Spot Size........................................................................................... 13 6. Field of View.......................................................................................................... 14 7. Thermocouple and ...

Page 8

Users Manual vi ...

Page 9

... The thermometers also support contact-temperature measurement via K-type thermocouple. Note that the Japanese models indicate Celsius only. Contacting Fluke To contact Fluke, call one of the following telephone numbers: USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 ...

Page 10

Users Manual Safety Information A Warning identifies conditions and actions that pose hazards to the user. To avoid personal injury, follow these guidelines: *Do not point laser directly at eye or indirectly off reflective surfaces. Replace the batteries as ...

Page 11

... Conforms to requirements of European Union and European Free Trade Association (EFTA) C Celsius F Fahrenheit M Battery Do not dispose of this product as unsorted municipal waste Fluke’s web site for ~ recycling information. „ China metrology certification mark for measuring instruments manufactured in the Peoples Republic of China (PRC). Laser Aperture Table 1 ...

Page 12

... Standard miniature K-type thermocouple connector input 80PK-1 K-type thermocouple probe Two AA batteries USB 2.0 computer interface cable (568) FlukeView Forms Documenting Software (568) Printed 566/568 Getting Started Guide 566/568 Manuals CD Display Language The thermometer display can show data in the following languages: ...

Page 13

... The reading is assigned a memory location and a time and date stamp. Figure 2. Menu Navigation Center Right Softkey Softkey Menu Light ε Menu Menu Avg Menu Alarm Menu Laser Menu - Infrared Thermometers Menu Overview eyl01.eps Description Adjust backlight brightness Set emissivity Enable Avg/Diff Set and enable alarms Toggle the laser on/off - 5 ...

Page 14

... Date/Time You may also press the Cancel softkey to abort saving the reading. Light The thermometers are equipped with a backlit display with two brightness levels. The Light softkey is used to adjust the backlight brightness. The backlight is on each time the trigger is pulled. To toggle the backlight brightness, press the Light softkey. ...

Page 15

... appears as the left softkey function. Press the corresponding softkey to change between the measurements. Min, Max, Avg, Differential The thermometers can measure minimum (MIN), maximum (MAX), average (AVG), or differential ( ) temperatures each time a reading is taken. These values are not shown if a thermocouple is plugged into the thermometer. ...

Page 16

... Min/Max or Avg/Dif mode is enabled. Alarm The thermometers have a programmable high and low alarm to designate high or low readings depending on the thresholds entered. When the alarm level is reached, an alarm will sound and the display will flash orange and white. To set either the high or low alarm: 1 ...

Page 17

... Select the date format: Day/Month/Year (dmy) or Month/Day/Year (mdy). 7. Use the up and down softkeys to change the selected parameter. 8. Press the Next softkey and the arrow softkeys to select the month, date, or year parameters. 9. Use the up and down softkeys to change the selected parameter. Infrared Thermometers Menu Overview 9 ...

Page 18

Users Manual 10. Press the Next softkey to move through each parameter. 11. Press the Done softkey when finished. The display reverts to the beginning of the Time/Date menu. Language To change the displayed language: 1. From the main ...

Page 19

... How the Thermometers Work Infrared thermometers measure the surface temperature of an object. The thermometer’s optics sense emitted, reflected, and transmitted energy, which is collected and focused onto a detector. The unit’s electronics translate the signal into a temperature reading which the unit displays (see Figure 3). ...

Page 20

Users Manual Locating a Hot or Cold Spot To find a hot or cold spot, aim the thermometer outside the desired area. Then, slowly scan across the area with an up and down motion until you locate the hot ...

Page 21

... As the distance (D) from the object being measured increases, the spot size (S) of the area measured by the unit becomes larger. The relationship between distance and spot size (D:S) for each unit is shown in Figure 5. The spot sizes indicate 90 % encircled energy. 568 Figure 5. Distance and Spot Size Infrared Thermometers Operating the Thermometer eyl06.eps 13 ...

Page 22

... The thermometers have numerically adjustable emissivity from 0.10 to 1.00 that can be used in conjunction with the emissivities in Table 3. Also, the thermometers have a built-in table of the most common materials that can be set from the Emissivity Menu. The built-in values are indicated in Table 3. ...

Page 23

... The stored data of the 568 can be downloaded to a personal computer (PC) via the included USB cable and the included FlukeView® Forms Documenting Software. See the FlukeView® Forms documentation for details. The USB input B is located on the top of the thermometer next to the external probe input A (see Figure 7). ...

Page 24

... The probe readings are shown below the non-contact measurements. The thermometer will stay on when there is a probe inserted. When used with a personal computer and FlukeView Forms (568 only), the auto off feature is disabled. Troubleshooting Use the following table to remedy possible problems when using the thermometer. ...

Page 25

... To install or change the two AA batteries (see Figure 8): 1. Slide the locking tab on the battery door to the “unlock” position and then open the handle. 2. Insert the batteries noting their correct polarity. 3. Close and lock the handle. Notes Note AA (+) Figure 8. Battery Replacement Infrared Thermometers Maintenance eyl04.eps 17 ...

Page 26

... Blow off loose particles using clean compressed air. Carefully wipe the surface with a water-moistened cotton swab. Cleaning the Housing Use soap and water on a damp sponge or soft cloth. To avoid damaging the thermometers, do NOT submerge them in water. Do not use abrasive cleaners, they will damage the case. User Replaceable Parts and Accessories User Replaceable Parts See Table 5 for a list of replaceable parts ...

Page 27

... The tapered probe is a good general-purpose gas and surface probe, with a good 80PK-26 length and low mass tip casing for faster reaction to surface and air temperatures. Infrared Thermometers User Replaceable Parts and Accessories Usage 19 ...

Page 28

Users Manual Specifications Feature IR Temperature Range Accuracy Repeatability Display Resolution Spectral Response Response Time (95%) K-Type Thermocouple Input Temperature Range K-Type Thermocouple Input Accuracy K-Type Thermocouple Resolution Distance:Spot (90% energy) Laser sighting Minimum spot size Emissivity Data storage ...

Page 29

... Typically Accuracy within 1.1 °C (2.0 °F) from -40 ° °C (-40 ° ° (40 in) K-type thermocouple cable with standard miniature Cable Length thermocouple connector and bead termination 566 K-Type Thermocouple Probe (Bead Type) Infrared Thermometers Specifications 568 21 ...

Page 30

Users Manual 22 ...