FLUKE-561 Fluke Electronics, FLUKE-561 Datasheet - Page 15

THERMOMETER HVACPRO IR

FLUKE-561

Manufacturer Part Number
FLUKE-561
Description
THERMOMETER HVACPRO IR
Manufacturer
Fluke Electronics
Series
561 HVACPror
Type
Handheld, Gunr
Datasheets

Specifications of FLUKE-561

Temperature Range
-40 ~ 1022°F (-40 ~ 550°C)
Temperature Display
C°/F°
Display Type
LCD
Input Type
Infrared; Thermocouple
Features
Backlight, Hold, Laser Sight, Min/Max/Dif/KTC
Probe Type
K
Battery Type
AA (2)
Includes
Case, Thermocouple - K-Type Pipe Probe
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2558118
561
614-1037
Troubleshooting
CE Certification
The Thermometer conforms to the following standards:
Certification testing was conducted using a frequency range of 80 to 1000 MHz with the
instrument in three orientations.
Specifications
--- (on display)
B
Blank display
Laser does not
work
Infrared
Measurement Range .................................................... -40 C to 550 C (-40 F to 1022 F)
Spectral Range............................................................. 8 to 14 microns
Accuracy ...................................................................... 1 % or
Repeatability................................................................. 0.5 % of reading or 1 C (2 F)
Display Resolution........................................................ 0.1 C (0.1 F)
Secondary Display Information..................................... Maximum, Minimum, Differential,
Response Time (95 %)................................................. 500 ms
Distance to Spot (D:S).................................................. 12:1
Emissivity Adjustment................................................... Three settings: low (0.3), medium
Contact Probe Input
Input Temperature Range ............................................ -40 C to 550 C (-40 F to 1022 F)
Input Accuracy...............................................................................Input accuracy
Display Resolution........................................................ 1 C (1 F)
Laser
Sighting ........................................................................ Single point laser
Power ........................................................................... Class 2 (II) operation; Output <1 mW,
Symptom
EN61326-1 EMC Standard
EN61010-1 Safety Standard
EN60825-1 Laser Standard
Target temperature is over or
under range
Low battery
Possible dead battery
1. Low or dead battery
2. Ambient temperature above
40 C (104 F)
Problem
ambient operating temperature of 23
to 25 C (73 to 77 F))
KTC
(0.7), high (0.95)
wavelength 630 to 670 nm
1 C (2 F)
Select target within
specifications
Replace battery
1. Replace battery
2. Use in area with lower
ambient temperature
Check and/or replace battery
1 C (2 F); <0 C (32 F),
Troubleshooting
0.1 /1 (Assumes
Action
1.1 C ( 2 F)
11