FLUKE-561 Fluke Electronics, FLUKE-561 Datasheet - Page 12

THERMOMETER HVACPRO IR

FLUKE-561

Manufacturer Part Number
FLUKE-561
Description
THERMOMETER HVACPRO IR
Manufacturer
Fluke Electronics
Series
561 HVACPror
Type
Handheld, Gunr
Datasheets

Specifications of FLUKE-561

Temperature Range
-40 ~ 1022°F (-40 ~ 550°C)
Temperature Display
C°/F°
Display Type
LCD
Input Type
Infrared; Thermocouple
Features
Backlight, Hold, Laser Sight, Min/Max/Dif/KTC
Probe Type
K
Battery Type
AA (2)
Includes
Case, Thermocouple - K-Type Pipe Probe
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2558118
561
614-1037
Users Manual
Switching Between C and F
Open the battery compartment and locate the switch positioned between the left side of the
battery near the Thermometer wall. To toggle between C and F, use a small screwdriver or
paper clip to move the switch to the desired position. See Figure 7.
8
Aluminum
Brass
Haynes
Inconel
Iron
Copper
Oxidized
Alloy A3003
Oxidized
Roughened
Burnished
Oxidized
Oxidized
Electrical Terminal
Blocks
Alloy
Oxidized
Sandblasted
Electoropolished
Oxidized
Rusted
Measured
Surface
Low
Low
Low
Low
Low
Medium
Medium
Medium
High, Medium
Medium
Low
High, Medium
Medium
Switch Setting
Table 2. Surface Emissivity
Iron, Cast
Iron, Wrought
Lead
Molybdenum
Platinum
Steel
Polished Sheet
Oxidized
Unoxidized
Molten
Dull
Rough
Oxidized
Oxidized
Nickel
Oxidized
Black
Cold-Rolled
Ground Sheet
Zinc
Oxidized
Measured
Surface
High, Medium
Low
Low
High
Low
Low, Medium
Low, Medium
Low
High
High
Medium
Low
Low
Switch Setting