TL76 Fluke Electronics, TL76 Datasheet - Page 54

no-image

TL76

Manufacturer Part Number
TL76
Description
TEST LEAD SET 2MM/4MM
Manufacturer
Fluke Electronics
Datasheet

Specifications of TL76

Current Rating
10A
Termination
Banana Plug, Sheathed, Right Angle
Color
Black and Red - Plugs, Probes and Wire
Cable Length
59.055" (1500.00mm)
Ratings
CAT IV, 600V; CAT III, 1000V
Wire Insulation Material
Silicone
Includes
Pin Tip, Lantern Tip (Removable)
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Voltage - Max
-
Impedance
-
Other names
2032684

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL7601G
Manufacturer:
SANYO
Quantity:
470
Part Number:
TL760M33QKVURQ1
0
Part Number:
TL7660CD
Manufacturer:
TI
Quantity:
12
Part Number:
TL7660CD
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7660CDGKRG4
Manufacturer:
TI
Quantity:
5 321
Part Number:
TL7660CDGKRG4
Manufacturer:
LT
Quantity:
973
Part Number:
TL7660CDGKT
Manufacturer:
Texas Instruments
Quantity:
135
Part Number:
TL7660CDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7660CDR
Quantity:
500
Company:
Part Number:
TL7660CDR
Quantity:
12 500
Part Number:
TL7660IDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
5
Heating, ventilation, air conditioning (HVAC) technicians require a
service tool that can consistently keep up with their demands. The
Fluke 902 expands the existing line of quality Fluke clamp meters by
delivering the features necessary to diagnose and repair HVAC systems.
Combined with True-rms technology and a CAT III 600 V rating, the
Fluke 902 helps technicians do their jobs safely and accurately.
Indoor Air Quality
Temperature
Relative humidity
Air velocity
CO
CO
Voltage dc
Voltage ac (True-rms)
Current ac (True-rms)
Current dc
Resistance
Continuity
Temperature Range
Capacitance
Designed for HVAC applications with capacitance, dc current (µA), and
temperature measurements
Small body and jaws fit perfectly in your hand and into tight places
Handy ‘Display Hold’ button keeps measurements on the display
Meter controls are positioned so current measurements can be done
with one hand (index finger on clamp opening lever and thumb on
rotary switch)
2
Fluke 902 True-rms HVAC Clamp Meter
0.25 m/sec to 15 m/sec
50.0 fpm to 3000 fpm
10 % to 90 % RH
(-5 °F to 122 °F)
non-condensing
-10 °C to 400 °C (-14 °F to 752 °F)
-20 °C to 50 °C
0 to 5000 ppm
-40 °C to -10 °C (-40 °F to -14 °F)
0 to 500 ppm
Range
Five powerful tools in one, with
0 - 9999 W
0 - 200 µA
1-1000 µF
0 - 600 V
0 - 600 V
0 - 600 A
Fluke 975 AirMeter
<= 30 W
Range
simple one-touch air velocity
The Fluke 975 test tool combines five powerful air
quality tools into one. Identify and diagnose indoor
air quality issues quickly and easily with one rugged,
handheld device. The Fluke 975 measures and simul-
taneously displays temperature, humidity, CO
At the press of a button, it quickly measures air flow
and percentage of outside air.
*Included with Fluke 975V, optional with Fluke 975
Display Resolution
1 fpm (0.005m/sec)
Simultaneously measures, logs, and displays
temperature, humidity, CO
backlit LCD display
One-touch air flow and velocity with available probe*
Wet bulb and dew point temperature
% of outside air calculation
CO
Automatically compensates for barometric pressure
changes
Min/Max/Average on all measured and calculated
readings
Audible and visual threshold alarms
Extensive discrete or continuous data logging
capacity, downloadable to PC via USB interface
0.1 °C (0.1 °F)
2
1 ppm
1 ppm
1 %
and CO field calibration feature
1.5 °F) typical +/-5.0 % + 1.5 °C
+/-1.0 % + 0.8 °C (+/-1.0 % +
(+/-5.0 % + 3.3 % °F) typical
2.0 % ± 5 counts (50/60 Hz)
1 % ± 5 counts (50/60 Hz)
1.0 % ± 5 counts
1.5 % ± 5 counts
1.9 % ± 2 counts
1 % ± 5 counts
Accuracy
± 0.9 °C/± 1.62°F from 40 °C to 60 °C ± 0.5 °C/±
1.00°F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from
-20 °C to 5 °C
± 2 % RH (10 % RH to 90 % RH)
±4 % or 4 fpm* ±4 % or 0.02 m/sec* whichever is
greater *Accuracy specification only valid for velocity
readings above 50 fpm.
Warm up time 1 min (5 minutes for full specification)
2.75 % + 75 ppm
± 5 % or ± 3 ppm, whichever is greater, @ 20 °C
and 50 % RH
Accuracy
2
, and CO on a bright,
Get more done
2
and CO.
Also available:
Fluke-975CK AirMeter Calibration
Kit includes the gases and tools
necessary to keep your Fluke 975
AirMeter calibrated.
Fluke-975AP AirMeter
Velocity Probe for use
with Fluke 975 AirMeter.
Included accessories
Fluke 975 includes: AA alkaline
batteries (3), Users manual (with
safety information), calibration cap,
hard carrying case, FlukeView
Forms software, power adapter, inter-
national power plugs, air velocity
probe (Fluke 975V only).
Fluke 902 includes: AA alkaline
batteries (2), Users manual (with
safety information), soft carrying
case, Tl75 Test Leads (1 pair), 80BK
Integrated Temperature Probe (1).
Ordering information
Fluke-975
Fluke-975V
Fluke-902
AirMeter
AirMeter
Velocity
HVAC Clamp Meter
with
®