TL76 Fluke Electronics, TL76 Datasheet - Page 24

no-image

TL76

Manufacturer Part Number
TL76
Description
TEST LEAD SET 2MM/4MM
Manufacturer
Fluke Electronics
Datasheet

Specifications of TL76

Current Rating
10A
Termination
Banana Plug, Sheathed, Right Angle
Color
Black and Red - Plugs, Probes and Wire
Cable Length
59.055" (1500.00mm)
Ratings
CAT IV, 600V; CAT III, 1000V
Wire Insulation Material
Silicone
Includes
Pin Tip, Lantern Tip (Removable)
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Voltage - Max
-
Impedance
-
Other names
2032684

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL7601G
Manufacturer:
SANYO
Quantity:
470
Part Number:
TL760M33QKVURQ1
0
Part Number:
TL7660CD
Manufacturer:
TI
Quantity:
12
Part Number:
TL7660CD
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7660CDGKRG4
Manufacturer:
TI
Quantity:
5 321
Part Number:
TL7660CDGKRG4
Manufacturer:
LT
Quantity:
973
Part Number:
TL7660CDGKT
Manufacturer:
Texas Instruments
Quantity:
135
Part Number:
TL7660CDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7660CDR
Quantity:
500
Company:
Part Number:
TL7660CDR
Quantity:
12 500
Part Number:
TL7660IDR
Manufacturer:
TI/德州仪器
Quantity:
20 000

For more information and detailed specifications, go to www.fluke.com/egt
Earth Ground Testers
Measure earth ground loop resistance
Earth ground tester for resistance measurement
Ground Clamp Meter
Handy GEO Earth Ground Tester
anywhere. Quickly and easily.
The Fluke 1630 Earth Ground Clamp is able to measure
ground loop resistances—using the Stakeless testing method.
This test technique eliminates the dangerous, and time
consuming activity of disconnecting parallel grounds, as
well as the process of finding suitable locations for auxiliary
ground stakes. You can also perform earth ground tests in
places you have not considered before: inside buildings, on
power pylons or anywhere you don’t have access to soil.
Ground clamp is placed around the earth ground rod or
the connecting cable. No earth ground stakes are used at
all. A known voltage is induced by one half of the clamp
and the current is measured by the other half. The tester
automatically determines the ground loop resistance at this
grounding connection. Gone are the days of spending time
placing and connecting stakes for each earth ground rod on
your system—a major time saver.
With the Stakeless testing method, the Fluke 1630 Earth
Quick and easy use—no earth ground stakes are
necessary
Large, 35 mm (1.35 in) jaw opening
Measures ground resistance from 0.025 W to 1500 W
Measures ground leakage current from 0.2 mA to 30 mA
High and Low alarming
Automatic self calibration
Rugged carrying case and resistance check loop included
Fluke 1630 Earth
The Handy GEO Earth Ground Tester is a rugged,
easy-to-use tester for three-pole ground resistance
measurements and two-pole ac resistance
measurements.
earth ground test electrodes and testing with the
Handy GEO. Earth ground resistance measurements
are used to ensure safe operation and reduce power
quality problems. The Handy GEO is extremely
lightweight making it ideal to test for lightning
protection levels and periodic check-ups during
routine maintenance.
resistance between electrical joints:
AC current can be used to confirm the low resistance
path in two directions simultaneously.
using classic fall of potential as well as selective and
stakeless methods.
Two-pole ac resistance is measured to confirm low
Fuse-to-fuse holder (to ensure there is no
overheating)
Bonding of ground earth connections
Additional bonding
Cable to terminal connections
The gold standard for measuring ground resistance
Earth ground resistance is measured by installing
What is ground, and what
does it do?
The NEC, National Electrical Code,
defines a ground as a “conducting
connection, whether intentional or
accidental between an electrical
circuit or equipment and the earth, or
to some conducting body that serves
in place of the earth.”
it is actually two different subjects,
earth grounding and equipment
grounding. Earth grounding is an
intentional connection from a circuit
conductor usually the neutral to a
ground electrode placed in the earth.
Equipment grounding is to ensure
that operating equipment within a
structure is properly grounded.
are required to be separate except
for a connection between the two
systems to prevent differences in
potential from a possible flashover
from a lightning strike. The purpose
of a ground besides the protection
of people, plants and equipment
is to provide a safe path for the
dissipation of fault currents, lightning
strikes, static discharges, EMI and
RFI signals and interference.
Included accessories
Fluke 1630 Clamp Meter: Rugged
carrying case with belt, resistance
test loop, 9 V battery and users
manual.
Handy GEO Tester: Rugged rubber
holster with carrying belt, battery,
and operating instructions.
Ordering information
Fluke-1630
Handy GEO
Handy GEO Kit Earth Ground Tester
These products are for unpowered
installations measuring grounding
connections.
When talking about grounding
These two grounding systems
Earth Ground
Clamp Meter
Earth Ground Tester
Kit with 25 m and
50 m cable reel
and two earth
ground stakes