XH414H-II06E Seiko Instruments, XH414H-II06E Datasheet - Page 6

CAP DOUBLE LAYER ELEC .07F 3.3V

XH414H-II06E

Manufacturer Part Number
XH414H-II06E
Description
CAP DOUBLE LAYER ELEC .07F 3.3V
Manufacturer
Seiko Instruments
Series
XHr
Datasheet

Specifications of XH414H-II06E

Capacitance
70mF
Voltage - Rated
3.3V
Mounting Type
Surface Mount
Package / Case
Surface Mount - Coin Style
Height
0.055" (1.40mm)
Size / Dimension
0.189" Dia (4.80mm)
Operating Temperature
-25°C ~ 70°C
Voltage Rating
3.3 Volts
Operating Temperature Range
- 25 C to + 70 C
Dimensions
4.8 mm Dia. x 1.4 mm L x 1.4 mm H
Product
Super Capacitors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Tolerance
-
Lead Spacing
-
Esr (equivalent Series Resistance)
-
Lifetime @ Temp.
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
728-1037-2
6. Measuring Methods
6-2. Capacity
6-1. Measuring Environment, Meters and Equipment
6-1-1: Environment
6-1-2: Dimensions
6-1-3: DC Voltmeter
6-1-4: DC Ammeter and AC Ammeter
6-1-5: Resistance
6-1-6: Initialization of capacitor
6-2-1. Discharge capacity
1) Charging condition:
2) Discharging condition:
Voltmeter with class 0.2 of JIS C 1102 (Electric indicating instrument) or meter with
same or better grade in accuracy, and its input impedance is over 10Mohm must
be used.
Ammeter with class 0.2 of JIS C 1102 (Electric indicating instrument) or meter with
same or better grade in accuracy must be used.
Resistance should include all resistance in external circuit and its tolerance must
be within +/-0.5%.
All measurements must be conducted after 30 minutes of short-circuit.
Testing and Measuring must be conducted under the environment of the normal
temperature (24+/-2°C) and the normal humidity (65+/-20%RH), if not specified.
For measuring dimension JIS B 7503 (Dial gauge), JIS B 7507 (Vernier caliper)
and JIS B 7502 (External micrometer) or meter with same grade in accuracy must
be used.
Charge capacitor by voltage of 3.3V through protective resistance of 100 ohms
for 5 hours.
Discharge the capacitor by using constant current of 20uA to 2.0V. Then the
capacity is calculated by the duration.
The electrical discharge by the fixed resistance of 100kohm is allowed as
substitution of 20uA in a fixed current ampere. However, the calculation of
capacity must be used the division mensuration.
Capacity
(
C
)
=
i
(
V
i
+
2
V
i
+
1
)
×
Rd
1
P.6/12
×
(
T
i
+
1
T
i
)
STDE-B-XH0414H02RII06E-0010-1

Related parts for XH414H-II06E