H5CX-AS-AC100-240 Omron, H5CX-AS-AC100-240 Datasheet - Page 16

RELAY TIMER DGTL TRANS 100-240V

H5CX-AS-AC100-240

Manufacturer Part Number
H5CX-AS-AC100-240
Description
RELAY TIMER DGTL TRANS 100-240V
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AS-AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Transistor
Voltage - Supply
100 ~ 240VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Circuit
-
Contact Rating @ Voltage
-
Other names
Z2372
Note: Order the Flush Mounting Adapter separately if it is lost or dam-
Hard Cover
Y92A-48
Flush Mounting Adapter
(provided with models with H5CX-A/AD/AS/ASD)
Mounting Track
PFP-100N, PFP-50N
End Plate
PFP-M
Y92F-30
4.5
15 25
aged.
Note: The values shown in parentheses are for the PFP-50N.
10
25
1,000 (500)
(See note.)
50
25
11.5
10
25 *
10
M4 x 8
pan head
screw
Soft Cover
Y92A-48F1
7.3±0.15
35±0.3
10
6.2
1
1.3
4.8
1.8
27±0.15
1
35.5 35.3
1.8
PFP-100N2
Spacer
PFP-S
4.5
15 25
Note: 1. Depending on the operating environment, the condition of
Note: Use Waterproof Packing to provide a level of water protection
(provided with models with H5CX-A/AD/AS/ASD)
Waterproof Packing
10
Y92S-29
25
2. The H5CX’s panel surface is water-resistive (conforming to
that complies with NEMA4, UL Type 4X, or IP66 standards. Or-
der the Waterproof Packing separately if it is lost or damaged.
Depending on the operating environment, the Waterproof
Packing may deteriorate, contract, or harden and so regular re-
placement is recommended.
resin products may deteriorate, and may shrink or become
harder. Therefore, it is recommended that resin products
are replaced regularly.
IP66) and so even if drops of water penetrate the gaps be-
tween the keys, there will be no adverse effect on internal
circuits. If, however, there is a possibility of oil being present
on the operator’s hands, use the Soft Cover. The Soft Cover
ensures protection equivalent to IP54 against oil. Do not,
however, use the H5CX in locations where it would come in
direct contact with oil.
1,000
25
10
25 15
5
44.3
35±0.3
16.5
12
16
27
24
34.8
1
H5CX-A/-L
16
1.5
29.2
16

Related parts for H5CX-AS-AC100-240