H5CX-AS-AC100-240 Omron, H5CX-AS-AC100-240 Datasheet - Page 10

RELAY TIMER DGTL TRANS 100-240V

H5CX-AS-AC100-240

Manufacturer Part Number
H5CX-AS-AC100-240
Description
RELAY TIMER DGTL TRANS 100-240V
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-AS-AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Transistor
Voltage - Supply
100 ~ 240VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Circuit
-
Contact Rating @ Voltage
-
Other names
Z2372
Voltage Inputs (PNP Inputs)
Voltage Input Signal Levels
High level (Input ON):
Low level (Input OFF):
Input resistance:
Note: The DC voltage must be 30 VDC max.
Operate with transistor OFF
H5CX-A@
H5CX-A11@
Sensor
No-contact Input
(NPN Transistor)
(Connection to NPN open
collector output sensor)
0 V
4.5 to 30 VDC
0 to 2 VDC
Approx. 4.7 kΩ
Operate with transistor ON
H5CX-A@
H5CX-A11@
Sensor
No-contact Input
(PNP Transistor)
(Connection to PNP open
collector output sensor)
0 V
Operate with relay ON
H5CX-A@
H5CX-A11@
Contact Input
0 V
H5CX-A/-L
10