Description
RELAY TIME DELAY 2PDT 125VDC
Manufacturer
Tyco Electronics
Series
E7000, AGASTATr
Datasheet

Specifications of 1-1423169-0

Relay Type
Integrated
Function
On-Delay
Circuit
DPDT (2 Form C)
Delay Time
5 Sec ~ 50 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
10A @ 240VAC
Voltage - Supply
125VDC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
E7012PD004
Specifications subject to change
Dimensions are for reference only.
Nuclear Qualified Time Delay Relays
Time Delay Information
All units are furnished with dials calibrated in
linear increments covering the range selected.
(See “Catalog Number Code”). In addition, time-
calibrated ranges B through K provide non-linear
adjustment from .2 second to the beginning of
the linear zone. For easiest adjustment and lowest
cost, the shortest time range suitable to the
application should be selected.
Repeat Accuracy
Repeat accuracy at any fixed temperature is
defined as:
*The repeat accuracy deviation (A
Repeat accuracy is obtained from the following
formula:
A
Where —
T
T
*NEMA part ICS 2-218.02
Repeat accuracy at any fixed temperature is ± 10%
of setting.
to 30 minutes) and I (6 to 60 minutes) time
ranges may be up to 15% longer than subsequent
delays, due to coil temperature rise.
repeat accuracy specification above.
Delay Setting
Dial calibrations are provided to minimize the
time required to set the unit to a specific delay.
Rotate the dial clockwise to increase the delay;
counter-clockwise to decrease it.
unit must be set to a very precise delay value:
1. Set dial to desired time delay. (On letter-
2. Record as many time delays as required to
3. If the recorded average delay is shorter than
4. Repeat step 2 after each adjustment, until
SPECIFICATIONS
delay relay is a measure of the maximum
deviation in the time-delay that will be
experienced in successive operations at any
particular time setting of the relay and for any
particular operating voltage or current.
1
2
R
calibrated units, this requires an approximation
of a percentage value between the arrowhead
“M” on the dial, which provides minimum
time, and the letter “E,” which provides
maximum time.)
establish a stable average.
the desired time, turn dial slightly clockwise; if
it is longer, turn dial counter-clockwise.
required delay is recorded.
= Maximum time delay.
= Minimum time delay.
The first time delay afforded by units with H (3
Dial calibration error is not included in the
The following procedure is recommended if the
= ± 100
(T
(T
1
1
- T
+ T
2
2
)
)
3
R
) of a time-
Because of the variety of environments in which
time delay relays are applied, we recommend a
re-check of the time delay after approximately
three hours of operation. If any change from the
initial time setting is apparent, the relay should be
reset to the desired delay. The time delay
accuracy should then be monitored on a monthly
basis for several months, and if no substantial
change in time delay has taken place, the
frequency of checking may be reduced. It is
recommended that this procedure be
incorporated in the Operating Instructions for
your equipment.
Contact Ratings – Nuclear
Resistive at 125VDC . . . . . . . . . . . . . . . 1.0 Amp.
Resistive at 120 VAC 60 Hz . . . . . . . . . 10.0 Amp.
Contact Ratings – Non-Nuclear
CONTACT CAPACITY IN AMPS
(Resistive Loads)
Four pole models add approximately 1-1/4" to the
maximum height of the basic model,
approximately 1/8" to the depth. They are
designed for vertical operation only.
Timing Adjustment
The AGASTAT E7000 Series is the first
electropneumatic timer to offer the ease of
adjustment and resetting of a calibrated dial head.
Discrete ranges covering a total span from .1
second to 60 minutes are available. (See table on
page 6.) Each has its own calibrated, clearly
identified dial. Timing is set by simply turning the
dial to the desired time value. In the zone of
approximately 25° separating the high and low
ends of timing ranges A, D, E, and K,
instantaneous operation (no time delay) will
occur. All other ranges produce an infinite time
delay when the dial is set in this zone.
120V 60 HZ
240V 60Hz
480V 60Hz
110VDC
Contact
Voltage
30VDC
Technical Support Center 1-800-522-6752
www.tycoelectronics.com
Min. 100,000
Operations
15.0
20.0
20.0
12.0
1.0
Electronics

Related parts for 1-1423169-0