1-1423169-0 Tyco Electronics, 1-1423169-0 Datasheet - Page 2

no-image

1-1423169-0

Manufacturer Part Number
1-1423169-0
Description
RELAY TIME DELAY 2PDT 125VDC
Manufacturer
Tyco Electronics
Series
E7000, AGASTATr
Datasheet

Specifications of 1-1423169-0

Relay Type
Integrated
Function
On-Delay
Circuit
DPDT (2 Form C)
Delay Time
5 Sec ~ 50 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
10A @ 240VAC
Voltage - Supply
125VDC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
E7012PD004
Specifications subject to change
Dimensions are for reference only.
Nuclear Qualified Time Delay Relays
Two basic operating types are available: On-delay
models provide a delay period on energization, at
the end of which the switch transfers the load
from one set of contacts to another. De-
energizing the unit during the delay period
immediately recycles the unit, readying it for
another full delay period on reenergization.
OPERATION
On-Delay Models, E7012
(Delay on pick-up)
Applying continuous voltage to the coil (L1-L2)
starts a time delay lasting for the preset time.
During this period the normally closed contacts
(3—5 and 4—6) remain closed. At the end of the
delay period the normally closed contacts break
and the normally open contacts (1—5 and 2—6)
make. The contacts remain in this transferred
position until the coil is deenergized, at which
time the switch instantaneously returns to its
original position.
delay period, will recycle the unit within .050
second. It will then provide a full delay period
upon reenergization, regardless of how often the
coil voltage is interrupted before the unit has
been permitted to “time-out” to its full delay
setting.
In off-delay models the switch transfers the
Deenergizing the coil, either during or after the
2
load immediately upon energization, and the delay
period does not begin until the unit is
deenergized. At the end of the delay period the
switch returns to its original position.
Reenergizing the unit during the delay period
immediately resets the timing, readying it for
another full delay period on deenergization. No
power is required during the timing period.
Applying voltage to the coil (for at least .050
second) will instantaneously transfer the switch,
breaking the normally closed contacts (1—5 and
2—6), and making the normally open contacts
(3—5 and 4—6). Contacts remain in this
transferred position as long as the coil is
energized. The time delay begins immediately
upon deenergization. At the end of the delay
period the switch returns to its normal position.
will immediately return the timing mechanism to
a point where it will provide a full delay period
upon subsequent deenergization. The switch
remains in the transferred position.
Four Pole Models, E7014, E7024.
With the addition of an extra switch block at the
bottom of the basic units, this version of the
E7000 Series offers four pole switch capacity
with simultaneous timing or two-step timing. The
two-step operation is achieved by factory
adjustment to your specifications.
Off-Delay Models, E7022
(Delay on drop-out)
Reenergizing the coil during the delay period
Technical Support Center 1-800-522-6752
www.tycoelectronics.com
Electronics