Specifications of H3AM-NS-C AC100-240

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3AM-NS-CAC100-240
H3AMNSCAC100240
■ Accessory (Order Separately)
Note: Supplied with H3AM-NS@-@-300 models.
Specifications
■ General
■ Time Ranges
Note: Instantaneous output is obtained by turning the time setting knob below "0" until the time setting knob stops.
■ Ratings
Note: The minimum applicable load:
Waterproof Packing
Operating mode
Screw tightening torque
Input type
Output type
Mounting method
Approved standards
H3AM-@@@-A
H3AM-@@@-B
H3AM-@@@-C
Rated supply voltage
Operating voltage range
Power reset (-NS)
Reset input time (-NSR)
Reset voltage range (-NSR)
Power consumption
Control output
Ambient temperature
Ambient humidity
H3AM-NS: 10 mA at 5 VDC (failure level: P, reference value)
H3AM-NSR: 100 mA at 5 VDC (failure level: P, reference value)
Model
Item
3
6
12
http://www.ia.omron.com/
Full scale on
dial
100 to 240 VAC (50/60 Hz)
85% to 110% of rated supply voltage
Minimum power-opening time: 0.5 s
Minimum input time:
H level: 85 to 264 VAC
L level: 0 to 10 VAC
Approx. 9 VA (Approx. 5 W)
Contact output: 5 A at 250 VAC, resistive load (cosφ = 1)
Operating: –10°C to 55°C (with no icing)
Storage:
Operating: 35% to 85%
Y92S-35 (See note.)
ON-delay
0.98 N·m (10 kgf) max.
Voltage input
Relay: DPDT
Flush/Panel mounting, no restriction on mounting angle.
UL 508, CSA C22.2 No. 14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1
---
---
0.2 to12 s
–25°C to 65°C (with no icing)
s
Model
0.5 to 30 s
1 to 60 s
2 to 120 s
0.5 s
10 s
0.05 to 3 min
0.1 to 6 min
0.2 to 12 min
min
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Set time unit
0.5 to 30 min
1 to 60 min
2 to 120 min
10 min
0.05 to 3 h
0.1 to 6 h
0.2 to 12 h
h (hour)
0.5 to 30 h
1 to 60 h
---
10 h (hour)