H3AM-NS-C AC100-240 Omron, H3AM-NS-C AC100-240 Datasheet

no-image

H3AM-NS-C AC100-240

Manufacturer Part Number
H3AM-NS-C AC100-240
Description
TIMER SOLID SATE W/O RESET
Manufacturer
Omron
Series
H3AMr
Datasheet

Specifications of H3AM-NS-C AC100-240

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3AM-NS-CAC100-240
H3AMNSCAC100240
Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have any
questions or comments. Refer to Safety Precautions on page 7.
Large Setting Dial and Moving Pointers Ideal
for Easy Operation and Monitoring
• Incorporating an easy-to-see large setting dial with moving
• Wide time-setting range of 0.2 s to 60 h (available through three
• Wide AC power supply range (100 to 240 VAC)
• IP65 watertight and dust-tight front panel.
• Approved by UL and CSA.
• Conforms to EN61812-1 and IEC60664-1
• Conforms to EMC standards.
• Six-language instruction manual provided.
• Programmable contact enables the building of a self-holding
• Memory retention (-NSR)
• Finger protection terminal block
• Enables easy sequence checks through instantaneous outputs
Model Number Legend
Ordering Information
■ List of Models
Note: The operation of the instantaneous contacts differs for the self-resetting and electric resetting systems. Refer to Timing Charts on page 5
1. Resetting System
100 to 240
VAC
Rated supply
H3AM - NS
pointers.
time-range model types)
4 kV for Low Voltage, and EMC Directives.
relay circuit as well as built-in instantaneous contact. (-NS)
for a zero set value at any time range.
Mechatronic Analog Timer
H3AM
None: Self-resetting
R:
voltage
for details.
Electric resetting
Self-resetting
Electric
resetting
1
http://www.ia.omron.com/
(See note.)
Resetting
system
-
2
-
3
DPDT contact output
(Time-limit output SPDT and
switchable SPDT
(time-limit ↔ instantaneous))
DPDT contact output
(Time-limit output SPDT and
instantaneous output SPDT)
Control output
2. Time Range
A:
B:
C:
0.5 s to 30 h
1 s to 60 h
0.2 s to 12 h
0.5 s to 30 h (30 s, 3 min,
H3AM-NS-A
H3AM-NSR-A
30 min, 3 h, 30 h)
3. Accessory
None: Without accessory
300: Waterproof Packing
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
(Y92S-35) provided
H3AM-NS-B
H3AM-NSR-B
1 s to 60 h (60 s, 6 min,
60 min, 6 h, 60 h)
Time range
0.2 s to 12 h (12 s, 120 s,
H3AM-NS-C
H3AM-NSR-C
12 min, 120 min, 12 h)
1

Related parts for H3AM-NS-C AC100-240

H3AM-NS-C AC100-240 Summary of contents

Page 1

... Programmable contact enables the building of a self-holding relay circuit as well as built-in instantaneous contact. (-NS) • Memory retention (-NSR) • Finger protection terminal block • Enables easy sequence checks through instantaneous outputs for a zero set value at any time range. Model Number Legend H3AM - Time Range 1 ...

Page 2

... Operating: –10°C to 55°C (with no icing) Storage: –25°C to 65°C (with no icing) Ambient humidity Operating: 35% to 85% Note: The minimum applicable load: H3AM-NS VDC (failure level: P, reference value) H3AM-NSR: 100 VDC (failure level: P, reference value) http://www.ia.omron.com/ Model Set time unit min ...

Page 3

... VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals 1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and reset input circuit (H3AM-NSR only) 1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other ...

Page 4

... Time setting knob (set time) Setting pointer (orange) Displays set value. Output Indicator (orange) Time Unit Indicator Note: The scale goes up to "3" with the H3AM-@-A and up to "6" with the H3AM-@-B. Time Unit Selector Applicable Time Unit Applicable time unit Full ...

Page 5

... Instantaneous contact NO (6-8) Power indicator (POWER) Power indicator (POWER) Output indicator (UP) Output indicator (UP) Note the set time, Rt’ is the reset application time, and t’ is the power interruption time. http://www.ia.omron.com Rt' Rt' Rt' Rt' t t+ (c)Copyright OMRON Corporation 2007 All Rights Reserved. H3AM 5 ...

Page 6

... Dimensions Note: All units are in millimeters unless otherwise indicated. H3AM (Flush Mounting ■ Accessories (Order Separately) Waterproof Packing (Provided with H3AM-NS@-@-300 models.) Y92S-35 Note: Use Waterproof Packing to provide a level of water protection Installation ■ Internal Connections and Terminal Arrangement H3AM- Power Supply ...

Page 7

... Observe the following items to ensure the safe use of this product. Environmental Precautions • Store the H3AM within the specified ratings. If the H3AM has been stored at temperatures –10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. ...

Page 8

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords