H3CR-A AC100-240/DC100-125 Omron, H3CR-A AC100-240/DC100-125 Datasheet - Page 11

RELAY TIMER DPDT ANALOG 120\240V

H3CR-A AC100-240/DC100-125

Manufacturer Part Number
H3CR-A AC100-240/DC100-125
Description
RELAY TIMER DPDT ANALOG 120\240V
Manufacturer
Omron
Series
H3CR-Ar

Specifications of H3CR-A AC100-240/DC100-125

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 240VAC
Voltage - Supply
100 ~ 240VAC, 100 ~ 125VDC
Termination Style
11 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Time Range
0.05 Sec. To 300 Hr.
Supply Voltage Ac, Min
100VAC
No. Of Timing Functions
6
Body Material
95B5375
No. Of Pins
11
Supply Voltage Ac, Max
240VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A AC100-240/DC100-125Q
H3CR-A-AC100-240
H3CR-A-AC100-240 DC1
H3CR-A-AC100-240 DC100-125
H3CRAAC100240DC100125
H3CRAAC100240DC100125Q
Z876
Operation
■ Timing Chart
Note: 1. The minimum power-opening time (“Rt”) is 0.1 s.
H3CR-A/-AS/-AP*
*H3CR-AP model incorporates start input only.
A: ON-delay
B:
Flicker OFF
start
B2:
Flicker ON
start
C:
Signal ON/
OFF-delay
Operating
mode
2. The minimum input pulse width (for start, reset) is 0.05 s.
3. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
4. Power supply start in mode J is also possible for H3CR-A8/-A8E/-A8S/-A8-301 models.
5. Refer to page 16 for application examples.
Output relay (NC)
Output relay (NO)
(Output indicator)
Output relay (NC)
Output relay (NO)
(Output indicator)
Output relay (NC)
Output relay (NO)
(Output indicator)
Output relay (NO)
(Output indicator)
Output relay (NC)
Power indicator
Power indicator
Power indicator
Power indicator
Power
Power
Power
Power
Reset
Reset
Reset
Reset
Start
Start
Start
Start
t
t
Timing chart
(See note)
(See note)
Basic operation
(See note)
Basic operation
Output
Basic operation
Power
Output
Power
Start
Output
Note: Start input is invalid while the
Start
Power
Note: Start input is invalid while the
Start
Note: Start input is invalid while
(See note)
Basic operation
Output
Power
Timer is in operation.
Start
Timer is in operation.
Note: Start input is valid and
the Timer is in operation.
t
t
t
retriggerable while the Timer
is in operation.
t
t
t
t
t
t
t
t
t
H3CR-A
t
11

Related parts for H3CR-A AC100-240/DC100-125