AQZ264 Panasonic Electric Works, AQZ264 Datasheet
AQZ264
Specifications of AQZ264
Related parts for AQZ264
AQZ264 Summary of contents
Page 1
... TYPICAL APPLICATIONS • Mercury relay replacement • Compact motors, lamps, heaters • OA equipment Packing quantity Inner carton 20 pcs AQZ264 Remarks 100Hz, Duty factor = 0.1% 400 V 1.0 A Peak AC, DC 3.0 A 100 ms (1shot), V ...
Page 2
... Within time µ max 100 0. 100 MHz 4 1,000 MΩ 500 0.5 cps Duty factor = 50 Max resistance vs. ambient temperature characteristics LED current: 10 mA; Continuous load current: 6A (DC)(AQZ262) 1A (DC)(AQZ264) 2 1.5 1 0.5 0 100 –40 – Ambient temperature, °C = Max. L AQZ264 AQZ262 ...
Page 3
... Turn off time vs. LED forward current characteristics Load voltage (DC); Continuous load current: 77°F 100 mA (DC); Ambient temperature: 25°C 0.6 0.5 AQZ262 0.4 0.3 0.2 AQZ264 0 LED forward current, mA 15.-(1) On resistance distribution Sample: AQZ262 LED current: 10 mA; Continuous load current (DC): 77° ...
Page 4
... LED dropout voltage distribution Sample: AQZ264 LED current: 50 mA; Quantity, n=100; Ambient temperature: 25°C 77°F 100 1.24 1.26 1.28 1.3 1.32 LED dropout voltage, V 16.-(2) Turn on time distribution Sample: AQZ264 Load voltage (DC); Continuous load current: 100 mA (DC); Quantity, n=100; Ambient temperature: 25°C 77° ...
Page 5
... All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 22.-(2) Low temperature storage test (change of on resistance) –40°F Quantity, n=10; Ambient temperature: –40°C AQZ262 2 AQZ264 1.6 1.2 0.8 0 Test time, h 212°F AQZ262 AQZ264 3 10 –40°F AQZ262 AQZ264 ...