AQ-HS-5A Panasonic, AQ-HS-5A Datasheet

no-image

AQ-HS-5A

Manufacturer Part Number
AQ-HS-5A
Description
Solid State Relays Heat sink for AQ1 solid state relay
Manufacturer
Panasonic
Datasheet

Specifications of AQ-HS-5A

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
AQ1
ORDERING INFORMATION
Load current
1 A, 2 A, 3 A, 5 A, 10 A
Load voltage
2:
D1:
D2:
Shape
Nil:
J:
Nil:
ZP:
ZT:
Input voltage
3/28 V DC: 3 to 28 V DC
4/32 V DC: 4 to 32 V DC
* Random types are available upon request.
Compliance with RoHS Directive
75 to 250 V AC
3 to 60 V DC
10 to 200 V DC
Vertical type
Flat type
DC output
Zero-cross AC output (Photocoupler)
Zero-cross AC output (Phototriac coupler)
AQ
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
FEATURES
1. 10A high-capacity realized for PC
board terminal (when using heat sink)
SSR for compact PC boards with 10 A
capacity that is two times greater than
our previous model. It is suitable for long-
life, highly frequent control.
2. VDE (EN60950-1) reinforced
insulation compliant
Fully satisfies demand for safety by
guaranteeing compliance with
EN60950-1 safety standard and featuring
3,000 V reinforced insulation (AQ3A2-
ZT4/32VDC, AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC).
3. Superior anti-vibration and anti-
shock characteristics
The body is molded as a single unit with
flame resistant resin which makes it
highly resistant against vibration and
shock, and gives it superior protection
from environment. The body can also be
washed.
4. Vertical types with SIL terminal
arrangement and flat types are
available.
1) The vertical type is available in
thicknesses of 10 mm (2 A and 3 A types)
and 12 mm (5 A and 10 A types).
Terminal arrangement is SIL in integral
multiples of 2.54 mm (0.1 inch).
2) The height of the flat type is 12 mm.
The terminal arrangement is DIL in
integral multiples of 2.54 mm.
High capacity up to 10A
PCB terminal type SSR
Certified
AQ2A2-ZP3/28VDC, AQ2A2-J-ZP3/28VDC,
AQ5A2-ZP3/28VDC, AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
Certified
AQ2A2-ZP3/28VDC, AQ2A2-J-ZP3/28VDC,
AQ5A2-ZP3/28VDC, AQ1AD2-3/28VDC
and AQ2AD1-3/28VDC
5. Reduced noise generation
The load will operate at close to zero
voltage even when the input signal is
applied during a cycle. Also, even if an
input signal is cancelled during a cycle,
the load is cut off at close to zero current.
For this reason, hardly any noise is
produced and radio frequency
interference (RFI) and electromagnetic
interference (EMI) are kept to a minimum.
6. Built-in snubber circuit prevents
malfunction.
TYPICAL APPLICATIONS
• Printing machines
• Packing machines
• Traffic signal control
• Automatic ticket punchers
• Terminal equipment of data processing
• Computer peripherals
• NC machines
AQ1 RELAYS
Please contact us about
TÜV certified products.
Certified
AQ2A2-ZP3/28VDC, AQ2A2-J-ZP3/28VDC,
AQ5A2-ZP3/28VDC, AQ1AD2-3/28VDC and
AQ2AD1-3/28VDC
VDE
Certified
AQ3A2-ZT4/32VDC,
AQ3A2-J-ZT4/32VDC and
AQ10A2-ZT4/32VDC

Related parts for AQ-HS-5A

AQ-HS-5A Summary of contents

Page 1

... VDE (EN60950-1) reinforced insulation compliant Fully satisfies demand for safety by guaranteeing compliance with EN60950-1 safety standard and featuring 3,000 V reinforced insulation (AQ3A2- ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC). 3. Superior anti-vibration and anti- shock characteristics The body is molded as a single unit with fl ...

Page 2

... Min. load current Notes: *1 When heat sink (AQ-HS-5A) is installed. The max. load current when heat sink is not installed. *2 When heat sink (AQ-HS-5A) is installed. The max. load current when heat sink is not installed. *3 When load current is below the rating, refer to “Cautions for Use”. ...

Page 3

... No. of cycles 1.-(2) Load current vs. ambient temperature (AC output type) Part No.: AQ10A2-ZT4/32VDC (A) When not using a heat sink (B) When using a standard heat sink AQ-HS-5A (When attached to a heat sink, use a heat conductive compound (Ex. Toshiba silicone YG6111 or TSK5303) of similar coating to improve cooling.) 10 (B) ...

Page 4

... A and 10 A types) Part No.: AQ3A2-ZT4/32VDC, AQ3A2-J-ZT4/32VDC and AQ10A2-ZT4/32VDC Input voltage, V 4.-(2) Load current vs. ambient temperature characteristics for adjacent mounting (AC output, 10A type) Part No.: AQ10A2-ZT4/32VDC (without heat sink =20.32mm .800inch Adjacent mounting pitch 1 0 -30 - 100 Ambient temperature, °C DIMENSIONS (mm inch) 1 ...

Page 5

... Copper foil 2.54 × 3 2.54 × 5 .100 × 5 .100 × 3 2.54 × 2 .100 × .787 .787 * There 2 holes are not necessary when not using heat sink (AQ-HS-5A) Schematic SSR LOAD INPUT – Load Load Input power source power source ±.020 13 ...

Page 6

... General tolerance: ±0.5 2. When a heat sink is mounted on the type The heat sink (AQ-HS-5A radiator which can make good contact should be used heat sink is used in which the contact condition is bad, a heat conducting compound should be used to improve the heat radiation ...

Related keywords