G3NA-205B-AC100-120 Omron, G3NA-205B-AC100-120 Datasheet - Page 4

RELAY SSR 5A@240VAC ZERO CROSS

G3NA-205B-AC100-120

Manufacturer Part Number
G3NA-205B-AC100-120
Description
RELAY SSR 5A@240VAC ZERO CROSS
Manufacturer
Omron
Series
G3NAr
Datasheets

Specifications of G3NA-205B-AC100-120

Control Voltage Range
100 VAC to 120 VAC
Load Current
5A
Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Voltage - Input
100 ~ 120VAC
Voltage - Load
19 ~ 264 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Load Voltage Rating
240 V
Off State Leakage Current (max)
5 mA, 10 mA
Load Current Rating
5 A
Contact Form
1 Form A
Output Device
Triac
Input To Output Isolation Method
Photocoupler
Relay Type
General Purpose Hockey Puck
Operating Voltage Range
19VAC To 264VAC
Isolation Voltage
2500VAC
Control Voltage Type
AC
Relay Terminals
Screw
Input Type
AC
Input Voltage (max)
132V
Output Voltage (max)
264V
Output Current
5A
Pin Count
4
Mounting
Screw
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NA205BAC100120
Z166

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G3NA-205B-AC100-120
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Dimensions
■ Relays
Note: All units are in millimeters unless otherwise indicated.
■ Optional Accessories (Order Separately)
One-touch Mounting Plate
The One-touch Mounting Plate is used to mount the G3NA to a DIN
Track.
R99-12 FOR G3NA (for the G3NA and G3NE)
470
G3NA-610B, G3NA-625B
G3NA-650B
Solid State Relays (600 VAC Models)
Two, M4 mounting
holes for the G3NE
58 max.
58 max.
Two, M5 x 12 screws
Two, M5 x 12 screws
47.5
47.5
12±0.4
12±0.4
44
44
30
44
Two, M4 mounting
holes for the G3NA
43 max.
43 max.
25
25
4.5
4.5
8.2
8.2
4.5 dia.
4.5 dia.
Two, M4 x 2
screws
Two, M4 x 2
screws
Operating
indicator
Operating
indicator
G3NA-6
• When a Relay is mounted to DIN Track, use it within the rating for a
• Use the following DIN Tracks: PFP-100N or PFP-100N2.
To mount the Relay to DIN
Track, first mount it to the
One-touch Mounting Plate
and then attach it to the DIN
Track as shown in the
diagram.
To remove the Relay from
the DIN Track, pull down on
the tab with a screwdriver in
the direction of the arrow.
28 max.
28 max.
26 max.
Relay without a heat sink.
26 max.
16.8
16.8
47.6
47.6
Mounting Holes
Mounting Holes
± 0.2
± 0.2
Two, 4.3-dia.
or M4 holes
Two, 4.3-dia.
or M4 holes
Terminal Arrangement/
Internal Connections
(Top View)
Terminal Arrangement/
Internal Connections
(Top View)
(−)
(−)
1
4
1
4
Output
Output
Input
Input
Load
Load
(+)
(+)
2
3
2
3
Load
power
supply
Load
power
supply