G3NA-205B-AC100-120 Omron, G3NA-205B-AC100-120 Datasheet - Page 2

RELAY SSR 5A@240VAC ZERO CROSS

G3NA-205B-AC100-120

Manufacturer Part Number
G3NA-205B-AC100-120
Description
RELAY SSR 5A@240VAC ZERO CROSS
Manufacturer
Omron
Series
G3NAr
Datasheets

Specifications of G3NA-205B-AC100-120

Control Voltage Range
100 VAC to 120 VAC
Load Current
5A
Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Voltage - Input
100 ~ 120VAC
Voltage - Load
19 ~ 264 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Load Voltage Rating
240 V
Off State Leakage Current (max)
5 mA, 10 mA
Load Current Rating
5 A
Contact Form
1 Form A
Output Device
Triac
Input To Output Isolation Method
Photocoupler
Relay Type
General Purpose Hockey Puck
Operating Voltage Range
19VAC To 264VAC
Isolation Voltage
2500VAC
Control Voltage Type
AC
Relay Terminals
Screw
Input Type
AC
Input Voltage (max)
132V
Output Voltage (max)
264V
Output Current
5A
Pin Count
4
Mounting
Screw
Operating Temp Range
-30C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3NA205BAC100120
Z166

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G3NA-205B-AC100-120
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Specifications
■ Ratings
Input (at an Ambient Temperature of 25°C)
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 240 VAC,
Output
Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data.
■ Characteristics
468
G3NA-6@@B
G3NA-610B
G3NA-625B
G3NA-650B
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Model
2. Refer to Temperature Characteristics (for Must Operate Voltage and Must Release Voltage) in Engineering Data for further details.
2. When an OMRON Heat Sink (refer to Options) or a heat sink of the specified size is used.
Model
the input impedance is measured at 240 VAC).
Item
Solid State Relays (600 VAC Models)
400 to 600 VAC
5 to 24 VDC
100 to 240 VAC
Rated load voltage
Rated voltage
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1/2 of load power source cycle + 1 ms max. (DC input)
3/2 of load power source cycle + 1 ms max. (AC input)
1.8 V (RMS) max.
10 mA max. (at 400 VAC)
20 mA max. (at 600 VAC)
100 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Operating:−30°C to 80°C (with no icing or condensation)
Storage: −30°C to 100°C (with no icing or condensation)
Operating: 45% to 85%
Approx. 120 g
G3NA-610B-UTU
Operating voltage
4 to 32 VDC
75 to 264 VAC
360 to 660 VAC
Load voltage range
2
7 mA max.
72 kΩ±20%
G3NA-6
(See note 1.)
Impedance
0.5 to 10 A (at 40°C)
0.5 to 25 A (at 40°C)
0.5 to 50 A (at 40°C)
With heat sink
Applicable load
(See note 2.)
G3NA-625B-UTU
Load current (See note 1.)
4 VDC max.
75 VAC max.
Must operate voltage
0.5 to 4 A (at 40°C)
0.5 to 4 A (at 40°C)
0.5 to 6 A (at 40°C)
Without heat sink
Voltage level
1 VDC min.
20 VAC min.
G3NA-650B-UTU
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
Must release voltage
Inrush current

Related parts for G3NA-205B-AC100-120